{"id":32596,"date":"2025-06-08T22:18:10","date_gmt":"2025-06-09T04:18:10","guid":{"rendered":"https:\/\/enertik.com\/mx\/?p=32596"},"modified":"2025-09-05T10:46:26","modified_gmt":"2025-09-05T16:46:26","slug":"guia-de-conexion-y-proteccion-en-sistemas-de-energia-solar-seguridad-eficiencia-y-continuidad","status":"publish","type":"post","link":"https:\/\/enertik.com\/mx\/blog\/otras-soluciones\/guia-de-conexion-y-proteccion-en-sistemas-de-energia-solar-seguridad-eficiencia-y-continuidad\/","title":{"rendered":"Gu\u00eda de conexi\u00f3n y protecci\u00f3n en sistemas de energ\u00eda solar: seguridad, eficiencia y continuidad"},"content":{"rendered":"\t\t<div data-elementor-type=\"wp-post\" data-elementor-id=\"32596\" class=\"elementor elementor-32596\" data-elementor-post-type=\"post\">\n\t\t\t\t\t\t<section class=\"wd-negative-gap elementor-section elementor-top-section elementor-element elementor-element-7eb6c52 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"7eb6c52\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-f3d0b61\" data-id=\"f3d0b61\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-1ca7d52 elementor-widget__width-initial color-scheme-inherit text-left elementor-widget elementor-widget-text-editor\" data-id=\"1ca7d52\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"409\" data-end=\"843\"><span style=\"color: #000000;\">En un sistema de energ\u00eda solar, no basta con tener buenos paneles, un regulador MPPT o un inversor de calidad. Lo que realmente asegura el rendimiento y la seguridad del sistema a largo plazo es la correcta <strong data-start=\"616\" data-end=\"651\">conexi\u00f3n y protecci\u00f3n el\u00e9ctrica<\/strong>. Cada cable, fusible y protecci\u00f3n contra sobretensiones cumple un rol vital para garantizar que la energ\u00eda fluya con eficiencia y que los equipos est\u00e9n protegidos ante cualquier eventualidad.<\/span><\/p><p data-start=\"845\" data-end=\"1050\"><span style=\"color: #000000;\">En este art\u00edculo, te presentamos los principales componentes de conexi\u00f3n y protecci\u00f3n en un sistema solar, explicando su funci\u00f3n, por qu\u00e9 son necesarios y c\u00f3mo elegir el tipo adecuado para cada aplicaci\u00f3n.<\/span><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"wd-negative-gap elementor-section elementor-top-section elementor-element elementor-element-d0c4314 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"d0c4314\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-c8a442e\" data-id=\"c8a442e\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-4b6a2ca elementor-widget elementor-widget-image\" data-id=\"4b6a2ca\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"768\" height=\"907\" src=\"https:\/\/enertik.com\/mx\/wp-content\/themes\/woodmart\/images\/lazy.svg\" class=\"attachment-medium_large size-medium_large wp-image-32601 wd-lazy-fade\" alt=\"Diagrama de un sistema solar, mostrando paneles, controlador, bater\u00edas e inversor.\" srcset=\"\" sizes=\"(max-width: 768px) 100vw, 768px\" data-src=\"https:\/\/enertik.com\/mx\/wp-content\/uploads\/sites\/4\/conexion-sistema-energia-solar-simple-768x907.webp\" data-srcset=\"https:\/\/enertik.com\/mx\/wp-content\/uploads\/sites\/4\/conexion-sistema-energia-solar-simple-768x907.webp 768w, https:\/\/enertik.com\/mx\/wp-content\/uploads\/sites\/4\/conexion-sistema-energia-solar-simple-254x300.webp 254w, https:\/\/enertik.com\/mx\/wp-content\/uploads\/sites\/4\/conexion-sistema-energia-solar-simple-867x1024.webp 867w, https:\/\/enertik.com\/mx\/wp-content\/uploads\/sites\/4\/conexion-sistema-energia-solar-simple-1300x1536.webp 1300w, https:\/\/enertik.com\/mx\/wp-content\/uploads\/sites\/4\/conexion-sistema-energia-solar-simple-430x508.webp 430w, https:\/\/enertik.com\/mx\/wp-content\/uploads\/sites\/4\/conexion-sistema-energia-solar-simple-700x827.webp 700w, https:\/\/enertik.com\/mx\/wp-content\/uploads\/sites\/4\/conexion-sistema-energia-solar-simple-150x177.webp 150w, https:\/\/enertik.com\/mx\/wp-content\/uploads\/sites\/4\/conexion-sistema-energia-solar-simple.webp 1346w\" title=\"\">\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">Conexi\u00f3n simple de un sistema de energ\u00eda solar<\/figcaption>\n\t\t\t\t\t\t\t\t\t\t<\/figure>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"wd-negative-gap elementor-section elementor-top-section elementor-element elementor-element-67cc6e4 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"67cc6e4\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-b2fe8fb\" data-id=\"b2fe8fb\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-f8a7be5 elementor-widget elementor-widget-heading\" data-id=\"f8a7be5\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h1 class=\"elementor-heading-title elementor-size-default\">1. Conexi\u00f3n y protecci\u00f3n entre paneles solares y el regulador MPPT o inversor solar<\/h1>\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"wd-negative-gap elementor-section elementor-top-section elementor-element elementor-element-6d4c487 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"6d4c487\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-39685df\" data-id=\"39685df\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-0c35bab color-scheme-inherit text-left elementor-widget elementor-widget-text-editor\" data-id=\"0c35bab\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<h3 style=\"text-align: center;\" data-start=\"1242\" data-end=\"1293\"><span style=\"text-decoration: underline;\"><span style=\"color: #000000;\"><strong data-start=\"1246\" data-end=\"1293\">Cables fotovoltaicos EN 50618 (XLPE o XLPO)<\/strong><\/span><\/span><\/h3>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"wd-negative-gap elementor-section elementor-top-section elementor-element elementor-element-166e285 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"166e285\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-55c010e\" data-id=\"55c010e\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-7b2e607 elementor-widget elementor-widget-image\" data-id=\"7b2e607\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"150\" height=\"150\" src=\"https:\/\/enertik.com\/mx\/wp-content\/themes\/woodmart\/images\/lazy.svg\" class=\"attachment-thumbnail size-thumbnail wp-image-32602 wd-lazy-fade\" alt=\"Rollos de cable rojo y negro, ideales para aplicaciones el\u00e9ctricas y t\u00e9cnicas.\" srcset=\"\" sizes=\"(max-width: 150px) 100vw, 150px\" data-src=\"https:\/\/enertik.com\/mx\/wp-content\/uploads\/sites\/4\/cable-fv-150x150.webp\" data-srcset=\"https:\/\/enertik.com\/mx\/wp-content\/uploads\/sites\/4\/cable-fv-150x150.webp 150w, https:\/\/enertik.com\/mx\/wp-content\/uploads\/sites\/4\/cable-fv-300x300.webp 300w, https:\/\/enertik.com\/mx\/wp-content\/uploads\/sites\/4\/cable-fv-1024x1024.webp 1024w, https:\/\/enertik.com\/mx\/wp-content\/uploads\/sites\/4\/cable-fv-768x768.webp 768w, https:\/\/enertik.com\/mx\/wp-content\/uploads\/sites\/4\/cable-fv-1536x1536.webp 1536w, https:\/\/enertik.com\/mx\/wp-content\/uploads\/sites\/4\/cable-fv-430x430.webp 430w, https:\/\/enertik.com\/mx\/wp-content\/uploads\/sites\/4\/cable-fv-700x700.webp 700w, https:\/\/enertik.com\/mx\/wp-content\/uploads\/sites\/4\/cable-fv.webp 2000w\" title=\"\">\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"wd-negative-gap elementor-section elementor-top-section elementor-element elementor-element-75ed705 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"75ed705\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-c72f2bf\" data-id=\"c72f2bf\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-77a55b8 elementor-widget__width-initial color-scheme-inherit text-left elementor-widget elementor-widget-text-editor\" data-id=\"77a55b8\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p style=\"text-align: left;\" data-start=\"1294\" data-end=\"1539\"><span style=\"color: #000000;\">Estos cables especiales transportan la corriente continua generada por los paneles hacia el regulador solar (controlador de carga solar) o las entradas del inversor fotovoltaico. Est\u00e1n dise\u00f1ados para resistir ambientes exigentes: <strong data-start=\"1468\" data-end=\"1538\">altas temperaturas, rayos UV, humedad, ozono y movimiento mec\u00e1nico<\/strong>.<\/span><\/p><hr \/><ul><li data-start=\"1543\" data-end=\"1626\"><span style=\"color: #000000;\"><strong data-start=\"1543\" data-end=\"1577\">XLPE (polietileno reticulado):<\/strong> ofrece excelente resistencia t\u00e9rmica y mec\u00e1nica.<\/span><\/li><li data-start=\"1629\" data-end=\"1743\"><span style=\"color: #000000;\"><strong data-start=\"1629\" data-end=\"1663\">XLPO (poliolefina reticulada):<\/strong> mejora la resistencia al envejecimiento y al fuego, ideal para climas extremos.<\/span><\/li><\/ul><hr \/><ul style=\"text-align: left;\" data-start=\"1541\" data-end=\"1743\"><li><strong style=\"color: #000000;\" data-start=\"1745\" data-end=\"1760\">Unipolares:<\/strong><span style=\"color: #000000;\"> se usan en instalaciones con una sola polaridad por cable (positivo o negativo).<\/span><\/li><li data-start=\"1627\" data-end=\"1743\"><p data-start=\"1629\" data-end=\"1743\"><strong style=\"color: #000000;\" data-start=\"1844\" data-end=\"1858\">Bipolares:<\/strong><span style=\"color: #000000;\"> integran dos conductores en una sola envoltura, facilitando el tendido y organizaci\u00f3n.<\/span><\/p><\/li><\/ul><hr \/><p style=\"text-align: left;\" data-start=\"1947\" data-end=\"2186\"><span style=\"color: #000000;\"><br \/>\ud83d\udc49 <strong data-start=\"1950\" data-end=\"1970\">\u00bfC\u00f3mo se eligen?<br \/><\/strong><\/span><br data-start=\"1970\" data-end=\"1973\" \/><span style=\"color: #000000;\">Se eligen seg\u00fan la corriente que van a transportar (Isc de la matriz de paneles) y el largo del recorrido (secci\u00f3n transversal en mm\u00b2), el entorno como la temperatura, exposici\u00f3n al sol, instalaci\u00f3n enterrada o a\u00e9rea (XLPE o XLPO) y si se necesita reducir la cantidad de cables (unipolar : un cable positivo y un cable negativo ; bipolar : un cable que cubre el polo positivo y el polo negativo.)<\/span><\/p><p style=\"text-align: left;\" data-start=\"1947\" data-end=\"2186\"><span style=\"color: #000000;\">A continuaci\u00f3n, te presentamos una tabla de referencia para la elecci\u00f3n del secci\u00f3n transversal adecuado :<\/span><\/p><table dir=\"ltr\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\" data-sheets-root=\"1\" data-sheets-baot=\"1\"><colgroup> <col width=\"169\" \/> <col width=\"100\" \/> <col width=\"100\" \/> <col width=\"100\" \/> <col width=\"100\" \/> <col width=\"100\" \/><\/colgroup><tbody><tr><td><span style=\"color: #000000;\"><strong>Corriente m\u00e1x. \/ Distancia<\/strong><\/span><\/td><td><span style=\"color: #000000;\"><strong>3 m<\/strong><\/span><\/td><td><span style=\"color: #000000;\"><strong>5 m<\/strong><\/span><\/td><td><span style=\"color: #000000;\"><strong>7 m<\/strong><\/span><\/td><td><span style=\"color: #000000;\"><strong>10 m<\/strong><\/span><\/td><td><span style=\"color: #000000;\"><strong>15 m<\/strong><\/span><\/td><\/tr><tr><td><span style=\"color: #000000;\"><strong>10 A<\/strong><\/span><\/td><td><span style=\"color: #000000;\">2.5 mm\u00b2<\/span><\/td><td><span style=\"color: #000000;\">4 mm\u00b2<\/span><\/td><td><span style=\"color: #000000;\">6 mm\u00b2<\/span><\/td><td><span style=\"color: #000000;\">10 mm\u00b2<\/span><\/td><td><span style=\"color: #000000;\">16 mm\u00b2<\/span><\/td><\/tr><tr><td><span style=\"color: #000000;\"><strong>20 A<\/strong><\/span><\/td><td><span style=\"color: #000000;\">4 mm\u00b2<\/span><\/td><td><span style=\"color: #000000;\">6 mm\u00b2<\/span><\/td><td><span style=\"color: #000000;\">10 mm\u00b2<\/span><\/td><td><span style=\"color: #000000;\">16 mm\u00b2<\/span><\/td><td><span style=\"color: #000000;\">25 mm\u00b2<\/span><\/td><\/tr><tr><td><span style=\"color: #000000;\"><strong>30 A<\/strong><\/span><\/td><td><span style=\"color: #000000;\">6 mm\u00b2<\/span><\/td><td><span style=\"color: #000000;\">10 mm\u00b2<\/span><\/td><td><span style=\"color: #000000;\">16 mm\u00b2<\/span><\/td><td><span style=\"color: #000000;\">25 mm\u00b2<\/span><\/td><td><span style=\"color: #000000;\">35 mm\u00b2<\/span><\/td><\/tr><\/tbody><\/table>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"wd-negative-gap elementor-section elementor-top-section elementor-element elementor-element-6840389 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"6840389\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-04feab4\" data-id=\"04feab4\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-24d09a9 color-scheme-inherit text-left elementor-widget elementor-widget-text-editor\" data-id=\"24d09a9\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<h3 style=\"text-align: center;\" data-start=\"1242\" data-end=\"1293\"><span style=\"text-decoration: underline; color: #000000;\">Conectores MC4<\/span><\/h3>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"wd-negative-gap elementor-section elementor-top-section elementor-element elementor-element-b76c14d elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"b76c14d\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-top-column elementor-element elementor-element-274e3cd\" data-id=\"274e3cd\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-6e404ff elementor-widget elementor-widget-image\" data-id=\"6e404ff\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"150\" height=\"150\" src=\"https:\/\/enertik.com\/mx\/wp-content\/themes\/woodmart\/images\/lazy.svg\" class=\"attachment-thumbnail size-thumbnail wp-image-32604 wd-lazy-fade\" alt=\"Conectores MC4 para paneles solares, dise\u00f1ados para conexiones el\u00e9ctricas seguras y resistentes al clima.\" srcset=\"\" sizes=\"(max-width: 150px) 100vw, 150px\" data-src=\"https:\/\/enertik.com\/mx\/wp-content\/uploads\/sites\/4\/mc4-connector-for-solar-panels-150x150.webp\" data-srcset=\"https:\/\/enertik.com\/mx\/wp-content\/uploads\/sites\/4\/mc4-connector-for-solar-panels-150x150.webp 150w, https:\/\/enertik.com\/mx\/wp-content\/uploads\/sites\/4\/mc4-connector-for-solar-panels-300x300.webp 300w, https:\/\/enertik.com\/mx\/wp-content\/uploads\/sites\/4\/mc4-connector-for-solar-panels-768x768.webp 768w, https:\/\/enertik.com\/mx\/wp-content\/uploads\/sites\/4\/mc4-connector-for-solar-panels-430x430.webp 430w, https:\/\/enertik.com\/mx\/wp-content\/uploads\/sites\/4\/mc4-connector-for-solar-panels-700x700.webp 700w, https:\/\/enertik.com\/mx\/wp-content\/uploads\/sites\/4\/mc4-connector-for-solar-panels.webp 800w\" title=\"\">\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-top-column elementor-element elementor-element-8e721b8\" data-id=\"8e721b8\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-85f656c elementor-widget elementor-widget-image\" data-id=\"85f656c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"150\" height=\"150\" src=\"https:\/\/enertik.com\/mx\/wp-content\/themes\/woodmart\/images\/lazy.svg\" class=\"attachment-thumbnail size-thumbnail wp-image-32605 wd-lazy-fade\" alt=\"Conectores MC4 de pl\u00e1stico duradero con dise\u00f1o de bloqueo y sellado para aplicaciones electr\u00f3nicas.\" srcset=\"\" sizes=\"(max-width: 150px) 100vw, 150px\" data-src=\"https:\/\/enertik.com\/mx\/wp-content\/uploads\/sites\/4\/conectores-mc4-en-y-150x150.webp\" data-srcset=\"https:\/\/enertik.com\/mx\/wp-content\/uploads\/sites\/4\/conectores-mc4-en-y-150x150.webp 150w, https:\/\/enertik.com\/mx\/wp-content\/uploads\/sites\/4\/conectores-mc4-en-y-300x300.webp 300w, https:\/\/enertik.com\/mx\/wp-content\/uploads\/sites\/4\/conectores-mc4-en-y-1024x1024.webp 1024w, https:\/\/enertik.com\/mx\/wp-content\/uploads\/sites\/4\/conectores-mc4-en-y-768x768.webp 768w, https:\/\/enertik.com\/mx\/wp-content\/uploads\/sites\/4\/conectores-mc4-en-y-1536x1536.webp 1536w, https:\/\/enertik.com\/mx\/wp-content\/uploads\/sites\/4\/conectores-mc4-en-y-430x430.webp 430w, https:\/\/enertik.com\/mx\/wp-content\/uploads\/sites\/4\/conectores-mc4-en-y-700x700.webp 700w, https:\/\/enertik.com\/mx\/wp-content\/uploads\/sites\/4\/conectores-mc4-en-y.webp 2000w\" title=\"\">\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"wd-negative-gap elementor-section elementor-top-section elementor-element elementor-element-0343241 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"0343241\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-c06ed57\" data-id=\"c06ed57\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-df43083 elementor-widget__width-initial color-scheme-inherit text-left elementor-widget elementor-widget-text-editor\" data-id=\"df43083\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"2242\" data-end=\"2412\"><span style=\"color: #000000;\">Permiten conectar paneles solares de manera segura y eficiente. Los conectores tipo MC4 garantizan <strong data-start=\"2341\" data-end=\"2410\">contacto firme, conexi\u00f3n estanca (IP67) y resistencia al desgaste<\/strong>.<\/span><\/p><ul data-start=\"2414\" data-end=\"2586\"><li data-start=\"2414\" data-end=\"2466\"><p data-start=\"2416\" data-end=\"2466\"><span style=\"color: #000000;\">Los conectores \u201c<strong data-start=\"2432\" data-end=\"2441\">1 a 1<\/strong>\u201d unen un panel con otro.<\/span><\/p><\/li><li data-start=\"2467\" data-end=\"2586\"><p data-start=\"2469\" data-end=\"2586\"><span style=\"color: #000000;\">Los \u201c<strong data-start=\"2474\" data-end=\"2483\">2 a 1<\/strong>\u201d, \u201c<strong>3 a 1<\/strong>\u201d y m\u00e1s, permiten unir en paralelo varios paneles a una sola entrada del inversor o regulador.<\/span><\/p><\/li><\/ul><hr \/><p data-start=\"2588\" data-end=\"2735\"><span style=\"color: #000000;\"><br \/>\ud83d\udc49 <strong data-start=\"2591\" data-end=\"2611\">\u00bfC\u00f3mo se eligen?<br \/><\/strong><\/span><br data-start=\"2611\" data-end=\"2614\" \/><span style=\"color: #000000;\">Seg\u00fan el dise\u00f1o del arreglo (serie\/paralelo) y el n\u00famero de paneles que deban conectarse en paralelo a una misma entrada.<\/span><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"wd-negative-gap elementor-section elementor-top-section elementor-element elementor-element-3a207bd elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"3a207bd\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-49418cf\" data-id=\"49418cf\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-151ceac color-scheme-inherit text-left elementor-widget elementor-widget-text-editor\" data-id=\"151ceac\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<h3 style=\"text-align: center;\" data-start=\"2742\" data-end=\"2811\"><span style=\"text-decoration: underline;\">Protector t\u00e9rmico CC para paneles solares<\/span><\/h3>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"wd-negative-gap elementor-section elementor-top-section elementor-element elementor-element-92ece4d elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"92ece4d\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-top-column elementor-element elementor-element-650f723\" data-id=\"650f723\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-cca7da7 elementor-widget elementor-widget-image\" data-id=\"cca7da7\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"150\" height=\"150\" src=\"https:\/\/enertik.com\/mx\/wp-content\/themes\/woodmart\/images\/lazy.svg\" class=\"attachment-thumbnail size-thumbnail wp-image-32607 wd-lazy-fade\" alt=\"Circuito breaker no polarizado de 500V con dos polos para protecci\u00f3n el\u00e9ctrica segura.\" srcset=\"\" sizes=\"(max-width: 150px) 100vw, 150px\" data-src=\"https:\/\/enertik.com\/mx\/wp-content\/uploads\/sites\/4\/protector-termico-dc-500v-2p-lktb1-50-150x150.webp\" data-srcset=\"https:\/\/enertik.com\/mx\/wp-content\/uploads\/sites\/4\/protector-termico-dc-500v-2p-lktb1-50-150x150.webp 150w, https:\/\/enertik.com\/mx\/wp-content\/uploads\/sites\/4\/protector-termico-dc-500v-2p-lktb1-50-300x300.webp 300w, https:\/\/enertik.com\/mx\/wp-content\/uploads\/sites\/4\/protector-termico-dc-500v-2p-lktb1-50-768x768.webp 768w, https:\/\/enertik.com\/mx\/wp-content\/uploads\/sites\/4\/protector-termico-dc-500v-2p-lktb1-50-430x430.webp 430w, https:\/\/enertik.com\/mx\/wp-content\/uploads\/sites\/4\/protector-termico-dc-500v-2p-lktb1-50-700x700.webp 700w, https:\/\/enertik.com\/mx\/wp-content\/uploads\/sites\/4\/protector-termico-dc-500v-2p-lktb1-50.webp 1000w\" title=\"\">\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-top-column elementor-element elementor-element-48f789c\" data-id=\"48f789c\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-122cc12 elementor-widget elementor-widget-image\" data-id=\"122cc12\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"150\" height=\"150\" src=\"https:\/\/enertik.com\/mx\/wp-content\/themes\/woodmart\/images\/lazy.svg\" class=\"attachment-thumbnail size-thumbnail wp-image-32608 wd-lazy-fade\" alt=\"Interruptor diferencial doble de 32A, con capacidad de 6kA y dise\u00f1o conforme a IEC.\" srcset=\"\" sizes=\"(max-width: 150px) 100vw, 150px\" data-src=\"https:\/\/enertik.com\/mx\/wp-content\/uploads\/sites\/4\/lktb1-50pv-c32-ver2-150x150.webp\" data-srcset=\"https:\/\/enertik.com\/mx\/wp-content\/uploads\/sites\/4\/lktb1-50pv-c32-ver2-150x150.webp 150w, https:\/\/enertik.com\/mx\/wp-content\/uploads\/sites\/4\/lktb1-50pv-c32-ver2-300x300.webp 300w, https:\/\/enertik.com\/mx\/wp-content\/uploads\/sites\/4\/lktb1-50pv-c32-ver2-1024x1024.webp 1024w, https:\/\/enertik.com\/mx\/wp-content\/uploads\/sites\/4\/lktb1-50pv-c32-ver2-768x768.webp 768w, https:\/\/enertik.com\/mx\/wp-content\/uploads\/sites\/4\/lktb1-50pv-c32-ver2-430x430.webp 430w, https:\/\/enertik.com\/mx\/wp-content\/uploads\/sites\/4\/lktb1-50pv-c32-ver2-700x700.webp 700w, https:\/\/enertik.com\/mx\/wp-content\/uploads\/sites\/4\/lktb1-50pv-c32-ver2.webp 1200w\" title=\"\">\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"wd-negative-gap elementor-section elementor-top-section elementor-element elementor-element-aa7a747 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"aa7a747\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-479c1ed\" data-id=\"479c1ed\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-f9dbce2 elementor-widget__width-initial color-scheme-inherit text-left elementor-widget elementor-widget-text-editor\" data-id=\"f9dbce2\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p><span style=\"color: #000000;\">En los sistemas fotovoltaicos, se emplean un <strong data-start=\"342\" data-end=\"420\">protector t\u00e9rmico (disyuntor t\u00e9rmico-magn\u00e9tico) de corriente continua (CC)<\/strong> para cada l\u00ednea de paneles solares que entra en el regulador solar \/ inversor solar, para protegerlos de las irregularidades el\u00e9ctricas.<\/span><\/p><p><span style=\"color: #000000;\">Este tipo de protecci\u00f3n t\u00e9rmica act\u00faa autom\u00e1ticamente ante sobrecargas sostenidas o cortocircuitos, interrumpiendo el paso de corriente cuando se supera el umbral t\u00e9rmico o magn\u00e9tico establecido. Su principal ventaja frente al fusible es que <strong data-start=\"791\" data-end=\"843\">puede rearmarse manualmente tras una desconexi\u00f3n<\/strong>, facilitando la recuperaci\u00f3n del sistema sin necesidad de reemplazar componentes.<\/span><\/p><hr \/><p>\u00a0<\/p><p data-start=\"927\" data-end=\"978\"><span style=\"color: #000000;\">\ud83d\udc49 <strong data-start=\"2591\" data-end=\"2611\">\u00bfC\u00f3mo se eligen?<\/strong><\/span><\/p><p><span style=\"color: #000000;\">Para elegir correctamente un protector t\u00e9rmico CC en esta secci\u00f3n del sistema, se deben tener en cuenta:<\/span><\/p><ul data-start=\"1086\" data-end=\"1588\"><li data-start=\"1086\" data-end=\"1239\"><span style=\"color: #000000;\"><strong data-start=\"1088\" data-end=\"1109\">Corriente nominal<\/strong> del campo fotovoltaico (basada en la corriente de cortocircuito de los m\u00f3dulos, multiplicada por un factor de seguridad de 1.25).<\/span><\/li><li data-start=\"1240\" data-end=\"1373\"><span style=\"color: #000000;\"><strong data-start=\"1242\" data-end=\"1271\">Tensi\u00f3n m\u00e1xima de la matriz de paneles<\/strong>, que debe ser inferior a la capacidad nominal del interruptor (normalmente 250Vcc, 500Vcc o 1000Vcc).<\/span><\/li><li data-start=\"1374\" data-end=\"1466\"><span style=\"color: #000000;\">Compatibilidad con corriente continua: no todos los interruptores t\u00e9rmicos sirven para CC.<\/span><\/li><li data-start=\"1467\" data-end=\"1588\"><span style=\"color: #000000;\">Preferiblemente con curva de disparo tipo C o D, adecuada para cargas inductivas o fluctuaciones por irradiaci\u00f3n solar.<\/span><\/li><\/ul><hr \/><p>\u00a0<\/p><p data-start=\"1590\" data-end=\"1609\"><strong><span style=\"color: #000000;\">\ud83d\udccc Instalaci\u00f3n<\/span><\/strong><\/p><p><span style=\"color: #000000;\">El interruptor t\u00e9rmico debe instalarse entre los paneles y el regulador\/inversor, de forma accesible para facilitar su operaci\u00f3n o inspecci\u00f3n. En sistemas con strings m\u00faltiples, se recomienda <strong data-start=\"1845\" data-end=\"1893\">un interruptor por cada string independiente<\/strong>, asegurando una protecci\u00f3n selectiva.<\/span><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"wd-negative-gap elementor-section elementor-top-section elementor-element elementor-element-9fe4ce7 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"9fe4ce7\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-cf29021\" data-id=\"cf29021\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-fa83f55 color-scheme-inherit text-left elementor-widget elementor-widget-text-editor\" data-id=\"fa83f55\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<h3 style=\"text-align: center;\" data-start=\"2742\" data-end=\"2811\"><span style=\"text-decoration: underline; color: #000000;\"><strong data-start=\"2746\" data-end=\"2811\">Protector contra Descargas Atmosf\u00e9ricas CC (500Vcc \/ 1000Vcc)<\/strong><\/span><\/h3>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"wd-negative-gap elementor-section elementor-top-section elementor-element elementor-element-6536a2f elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"6536a2f\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-054b550\" data-id=\"054b550\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-024ff2c elementor-widget elementor-widget-image\" data-id=\"024ff2c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"150\" height=\"150\" src=\"https:\/\/enertik.com\/mx\/wp-content\/themes\/woodmart\/images\/lazy.svg\" class=\"attachment-thumbnail size-thumbnail wp-image-32609 wd-lazy-fade\" alt=\"Protector de descargas atmosf\u00e9ricas LKTD2-PV500 de 500 VDC para sistemas el\u00e9ctricos.\" srcset=\"\" sizes=\"(max-width: 150px) 100vw, 150px\" data-src=\"https:\/\/enertik.com\/mx\/wp-content\/uploads\/sites\/4\/protector-de-descargas-atmosfericas-500vcc-2p-lktd2-pv500-150x150.webp\" data-srcset=\"https:\/\/enertik.com\/mx\/wp-content\/uploads\/sites\/4\/protector-de-descargas-atmosfericas-500vcc-2p-lktd2-pv500-150x150.webp 150w, https:\/\/enertik.com\/mx\/wp-content\/uploads\/sites\/4\/protector-de-descargas-atmosfericas-500vcc-2p-lktd2-pv500-300x300.webp 300w, https:\/\/enertik.com\/mx\/wp-content\/uploads\/sites\/4\/protector-de-descargas-atmosfericas-500vcc-2p-lktd2-pv500-768x768.webp 768w, https:\/\/enertik.com\/mx\/wp-content\/uploads\/sites\/4\/protector-de-descargas-atmosfericas-500vcc-2p-lktd2-pv500-430x430.webp 430w, https:\/\/enertik.com\/mx\/wp-content\/uploads\/sites\/4\/protector-de-descargas-atmosfericas-500vcc-2p-lktd2-pv500-700x700.webp 700w, https:\/\/enertik.com\/mx\/wp-content\/uploads\/sites\/4\/protector-de-descargas-atmosfericas-500vcc-2p-lktd2-pv500.webp 1000w\" title=\"\">\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"wd-negative-gap elementor-section elementor-top-section elementor-element elementor-element-50ac5cf elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"50ac5cf\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-4f41453\" data-id=\"4f41453\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-3b40723 elementor-widget__width-initial color-scheme-inherit text-left elementor-widget elementor-widget-text-editor\" data-id=\"3b40723\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"2812\" data-end=\"3040\"><span style=\"color: #000000;\">Protegen al inversor o al regulador ante <strong data-start=\"2853\" data-end=\"2926\">sobretensiones causadas por rayos o inducciones atmosf\u00e9ricas cercanas<\/strong>. Aunque no haya un impacto directo, un rayo que cae cerca puede inducir una sobretensi\u00f3n peligrosa en las l\u00edneas y romper <strong>de forma irreversible<\/strong> los equipos conectados, produciendo p\u00e9rdidas de inversi\u00f3n considerables. Este es el protector que la gente suele olvidar u omitir y despu\u00e9s arrepentirse de no haberlo instalado.<\/span><\/p><ul data-start=\"3042\" data-end=\"3255\"><li data-start=\"3042\" data-end=\"3135\"><p data-start=\"3044\" data-end=\"3135\"><span style=\"color: #000000;\"><strong data-start=\"3044\" data-end=\"3055\">500Vcc:<\/strong> para instalaciones de baja tensi\u00f3n (ej. sistemas peque\u00f1os o con pocos paneles).<\/span><\/p><\/li><li data-start=\"3136\" data-end=\"3255\"><p data-start=\"3138\" data-end=\"3255\"><span style=\"color: #000000;\"><strong data-start=\"3138\" data-end=\"3150\">1000Vcc:<\/strong> para sistemas con muchas paneles en serie, t\u00edpicos en instalaciones residenciales o comerciales medianas.<\/span><\/p><\/li><\/ul><hr \/><p data-start=\"3257\" data-end=\"3417\"><span style=\"color: #000000;\"><br \/>\ud83d\udc49 <strong data-start=\"3260\" data-end=\"3280\">\u00bfC\u00f3mo se eligen?<br \/><\/strong><\/span><br data-start=\"3280\" data-end=\"3283\" \/><span style=\"color: #000000;\">En funci\u00f3n del voltaje m\u00e1ximo del arreglo fotovoltaico (Vmp y Voc del string).<\/span><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"wd-negative-gap elementor-section elementor-top-section elementor-element elementor-element-9c435f8 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"9c435f8\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-99e396c\" data-id=\"99e396c\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-7d82a2f color-scheme-inherit text-left elementor-widget elementor-widget-text-editor\" data-id=\"7d82a2f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<h3 style=\"text-align: center;\" data-start=\"5344\" data-end=\"5371\"><span style=\"text-decoration: underline; color: #000000;\"><strong data-start=\"5348\" data-end=\"5371\">Llave de corte CC<\/strong><\/span><\/h3>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"wd-negative-gap elementor-section elementor-top-section elementor-element elementor-element-2fa8f63 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"2fa8f63\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-b9191db\" data-id=\"b9191db\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-e3c42ae elementor-widget elementor-widget-image\" data-id=\"e3c42ae\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"150\" height=\"150\" src=\"https:\/\/enertik.com\/mx\/wp-content\/themes\/woodmart\/images\/lazy.svg\" class=\"attachment-thumbnail size-thumbnail wp-image-32610 wd-lazy-fade\" alt=\"Llave de corte SISO con conector MC4, 1000V CC, 32A, ideal para control el\u00e9ctrico.\" srcset=\"\" sizes=\"(max-width: 150px) 100vw, 150px\" data-src=\"https:\/\/enertik.com\/mx\/wp-content\/uploads\/sites\/4\/llave-de-corte-entrada-y-salida-con-mc4-1000vcc-32a-siso-32m-150x150.webp\" data-srcset=\"https:\/\/enertik.com\/mx\/wp-content\/uploads\/sites\/4\/llave-de-corte-entrada-y-salida-con-mc4-1000vcc-32a-siso-32m-150x150.webp 150w, https:\/\/enertik.com\/mx\/wp-content\/uploads\/sites\/4\/llave-de-corte-entrada-y-salida-con-mc4-1000vcc-32a-siso-32m-300x300.webp 300w, https:\/\/enertik.com\/mx\/wp-content\/uploads\/sites\/4\/llave-de-corte-entrada-y-salida-con-mc4-1000vcc-32a-siso-32m-430x430.webp 430w, https:\/\/enertik.com\/mx\/wp-content\/uploads\/sites\/4\/llave-de-corte-entrada-y-salida-con-mc4-1000vcc-32a-siso-32m.webp 500w\" title=\"\">\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"wd-negative-gap elementor-section elementor-top-section elementor-element elementor-element-64b6b38 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"64b6b38\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-fb4071b\" data-id=\"fb4071b\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-98b9e60 elementor-widget__width-initial color-scheme-inherit text-left elementor-widget elementor-widget-text-editor\" data-id=\"98b9e60\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"5372\" data-end=\"5563\"><span style=\"color: #000000;\">Una llave que permite <strong data-start=\"5394\" data-end=\"5443\">interrumpir manualmente la corriente continua<\/strong> entre paneles solares y el regulador \/ inversor solar para realizar mantenimientos o aislar una falla.\u00a0<\/span><\/p><hr \/><p data-start=\"5565\" data-end=\"5729\"><span style=\"color: #000000;\"><br \/>\ud83d\udc49<strong data-start=\"5568\" data-end=\"5587\">\u00bfC\u00f3mo se elige?<br \/><\/strong><\/span><br data-start=\"5587\" data-end=\"5590\" \/><span style=\"color: #000000;\">Seg\u00fan la tensi\u00f3n nominal de los paneles solares y la corriente m\u00e1xima esperada. Tambi\u00e9n debe cumplir con la normativa de desconexi\u00f3n segura.<\/span><\/p><p data-start=\"3257\" data-end=\"3417\">\u00a0<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"wd-negative-gap elementor-section elementor-top-section elementor-element elementor-element-e5bc89c elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"e5bc89c\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-4eb9166\" data-id=\"4eb9166\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-0146a95 elementor-widget elementor-widget-heading\" data-id=\"0146a95\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h1 class=\"elementor-heading-title elementor-size-default\">2. Conexi\u00f3n entre paneles solares<\/h1>\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"wd-negative-gap elementor-section elementor-top-section elementor-element elementor-element-8eaa6af elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"8eaa6af\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-bed1cd8\" data-id=\"bed1cd8\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-6c193eb color-scheme-inherit text-left elementor-widget elementor-widget-text-editor\" data-id=\"6c193eb\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<h3 style=\"text-align: center;\" data-start=\"2742\" data-end=\"2811\"><span style=\"text-decoration: underline; color: #000000;\">Fusibles solares gPV y portafusibles<\/span><\/h3>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"wd-negative-gap elementor-section elementor-top-section elementor-element elementor-element-65ffe75 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"65ffe75\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-top-column elementor-element elementor-element-7aeca77\" data-id=\"7aeca77\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-6d31e8e elementor-widget elementor-widget-image\" data-id=\"6d31e8e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"150\" height=\"150\" src=\"https:\/\/enertik.com\/mx\/wp-content\/themes\/woodmart\/images\/lazy.svg\" class=\"attachment-thumbnail size-thumbnail wp-image-32611 wd-lazy-fade\" alt=\"Fusible solar de 30A 1000VCC para sistemas fotovoltaicos, marca Enertik.\" srcset=\"\" sizes=\"(max-width: 150px) 100vw, 150px\" data-src=\"https:\/\/enertik.com\/mx\/wp-content\/uploads\/sites\/4\/fusible-solar-10x38mm-gpv-1000vcc-30a-sfus-30-150x150.webp\" data-srcset=\"https:\/\/enertik.com\/mx\/wp-content\/uploads\/sites\/4\/fusible-solar-10x38mm-gpv-1000vcc-30a-sfus-30-150x150.webp 150w, https:\/\/enertik.com\/mx\/wp-content\/uploads\/sites\/4\/fusible-solar-10x38mm-gpv-1000vcc-30a-sfus-30-300x300.webp 300w, https:\/\/enertik.com\/mx\/wp-content\/uploads\/sites\/4\/fusible-solar-10x38mm-gpv-1000vcc-30a-sfus-30-768x768.webp 768w, https:\/\/enertik.com\/mx\/wp-content\/uploads\/sites\/4\/fusible-solar-10x38mm-gpv-1000vcc-30a-sfus-30-430x430.webp 430w, https:\/\/enertik.com\/mx\/wp-content\/uploads\/sites\/4\/fusible-solar-10x38mm-gpv-1000vcc-30a-sfus-30-700x700.webp 700w, https:\/\/enertik.com\/mx\/wp-content\/uploads\/sites\/4\/fusible-solar-10x38mm-gpv-1000vcc-30a-sfus-30.webp 1000w\" title=\"\">\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-top-column elementor-element elementor-element-e7cd0fe\" data-id=\"e7cd0fe\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-415e7f9 elementor-widget elementor-widget-image\" data-id=\"415e7f9\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"150\" height=\"150\" src=\"https:\/\/enertik.com\/mx\/wp-content\/themes\/woodmart\/images\/lazy.svg\" class=\"attachment-thumbnail size-thumbnail wp-image-32612 wd-lazy-fade\" alt=\"Conector porta-fusible solar 1000V CC para instalaciones el\u00e9ctricas seguras y eficientes.\" srcset=\"\" sizes=\"(max-width: 150px) 100vw, 150px\" data-src=\"https:\/\/enertik.com\/mx\/wp-content\/uploads\/sites\/4\/porta-fusible-solar-gpv-1000vcc-spf-15-150x150.webp\" data-srcset=\"https:\/\/enertik.com\/mx\/wp-content\/uploads\/sites\/4\/porta-fusible-solar-gpv-1000vcc-spf-15-150x150.webp 150w, https:\/\/enertik.com\/mx\/wp-content\/uploads\/sites\/4\/porta-fusible-solar-gpv-1000vcc-spf-15-300x300.webp 300w, https:\/\/enertik.com\/mx\/wp-content\/uploads\/sites\/4\/porta-fusible-solar-gpv-1000vcc-spf-15-768x768.webp 768w, https:\/\/enertik.com\/mx\/wp-content\/uploads\/sites\/4\/porta-fusible-solar-gpv-1000vcc-spf-15-430x430.webp 430w, https:\/\/enertik.com\/mx\/wp-content\/uploads\/sites\/4\/porta-fusible-solar-gpv-1000vcc-spf-15-700x700.webp 700w, https:\/\/enertik.com\/mx\/wp-content\/uploads\/sites\/4\/porta-fusible-solar-gpv-1000vcc-spf-15.webp 1000w\" title=\"\">\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"wd-negative-gap elementor-section elementor-top-section elementor-element elementor-element-65179e2 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"65179e2\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-6750866\" data-id=\"6750866\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-f3c17fe elementor-widget__width-initial color-scheme-inherit text-left elementor-widget elementor-widget-text-editor\" data-id=\"f3c17fe\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"2742\" data-end=\"2811\"><span style=\"color: #000000;\">Los fusibles gPV est\u00e1n dise\u00f1ados espec\u00edficamente para corriente continua y para proteger paneles solares en caso de <strong data-start=\"3623\" data-end=\"3672\">cortocircuito entre strings o fallas internas<\/strong>.<\/span><\/p><ul data-start=\"3675\" data-end=\"3924\"><li data-start=\"3675\" data-end=\"3810\"><p data-start=\"3677\" data-end=\"3810\"><span style=\"color: #000000;\"><strong data-start=\"3677\" data-end=\"3684\">gPV<\/strong> significa \u201cgeneral photovoltaic\u201d, y asegura que el fusible podr\u00e1 cortar incluso peque\u00f1as corrientes de falla de forma segura.<\/span><\/p><\/li><li data-start=\"3811\" data-end=\"3924\"><p data-start=\"3813\" data-end=\"3924\"><span style=\"color: #000000;\">Se colocan generalmente en los polos positivos (y a veces en ambos) cuando hay conexi\u00f3n en paralelo de strings.<\/span><\/p><\/li><\/ul><hr \/><p data-start=\"3926\" data-end=\"4161\"><span style=\"color: #000000;\"><br \/>\ud83d\udc49 <strong data-start=\"3929\" data-end=\"3949\">\u00bfC\u00f3mo se eligen?<br \/><\/strong><\/span><br data-start=\"3949\" data-end=\"3952\" \/><span style=\"color: #000000;\">Seg\u00fan la corriente nominal de cortocircuito de cada string (Isc) y el n\u00famero de strings en paralelo. Se recomienda elegir un valor ligeramente superior al Isc pero inferior a la capacidad m\u00e1xima del cable.\u00a0<\/span><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"wd-negative-gap elementor-section elementor-top-section elementor-element elementor-element-8b8f185 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"8b8f185\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-376c75d\" data-id=\"376c75d\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-a803762 elementor-widget elementor-widget-heading\" data-id=\"a803762\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h1 class=\"elementor-heading-title elementor-size-default\">3. Conexi\u00f3n entre bater\u00edas y el inversor\n\n<\/h1>\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"wd-negative-gap elementor-section elementor-top-section elementor-element elementor-element-62396d5 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"62396d5\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-6c595ad\" data-id=\"6c595ad\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-72a8faf color-scheme-inherit text-left elementor-widget elementor-widget-text-editor\" data-id=\"72a8faf\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<h3 style=\"text-align: center;\" data-start=\"4213\" data-end=\"4242\"><span style=\"text-decoration: underline; color: #000000;\"><strong data-start=\"4217\" data-end=\"4242\">Cables de conexi\u00f3n CC<\/strong><\/span><\/h3>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"wd-negative-gap elementor-section elementor-top-section elementor-element elementor-element-26c5d5e elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"26c5d5e\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-33 elementor-top-column elementor-element elementor-element-9084162\" data-id=\"9084162\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-c310ece elementor-widget elementor-widget-image\" data-id=\"c310ece\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"150\" height=\"150\" src=\"https:\/\/enertik.com\/mx\/wp-content\/themes\/woodmart\/images\/lazy.svg\" class=\"attachment-thumbnail size-thumbnail wp-image-32613 wd-lazy-fade\" alt=\"Cable el\u00e9ctrico de cobre trenzado con aislamiento negro, ideal para aplicaciones en instalaciones el\u00e9ctricas.\" srcset=\"\" sizes=\"(max-width: 150px) 100vw, 150px\" data-src=\"https:\/\/enertik.com\/mx\/wp-content\/uploads\/sites\/4\/cable-25mm-negro-150x150.webp\" data-srcset=\"https:\/\/enertik.com\/mx\/wp-content\/uploads\/sites\/4\/cable-25mm-negro-150x150.webp 150w, https:\/\/enertik.com\/mx\/wp-content\/uploads\/sites\/4\/cable-25mm-negro-300x300.webp 300w, https:\/\/enertik.com\/mx\/wp-content\/uploads\/sites\/4\/cable-25mm-negro-768x768.webp 768w, https:\/\/enertik.com\/mx\/wp-content\/uploads\/sites\/4\/cable-25mm-negro-430x430.webp 430w, https:\/\/enertik.com\/mx\/wp-content\/uploads\/sites\/4\/cable-25mm-negro-700x700.webp 700w, https:\/\/enertik.com\/mx\/wp-content\/uploads\/sites\/4\/cable-25mm-negro.webp 1000w\" title=\"\">\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t<div class=\"elementor-column elementor-col-33 elementor-top-column elementor-element elementor-element-6e9a107\" data-id=\"6e9a107\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-f299ccb elementor-widget elementor-widget-image\" data-id=\"f299ccb\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"150\" height=\"150\" src=\"https:\/\/enertik.com\/mx\/wp-content\/themes\/woodmart\/images\/lazy.svg\" class=\"attachment-thumbnail size-thumbnail wp-image-32614 wd-lazy-fade\" alt=\"Cables el\u00e9ctricos rojo y negro para conexiones de bater\u00eda en proyectos automotrices.\" srcset=\"\" sizes=\"(max-width: 150px) 100vw, 150px\" data-src=\"https:\/\/enertik.com\/mx\/wp-content\/uploads\/sites\/4\/61amuvxtqcl-150x150.webp\" data-srcset=\"https:\/\/enertik.com\/mx\/wp-content\/uploads\/sites\/4\/61amuvxtqcl-150x150.webp 150w, https:\/\/enertik.com\/mx\/wp-content\/uploads\/sites\/4\/61amuvxtqcl-300x300.webp 300w, https:\/\/enertik.com\/mx\/wp-content\/uploads\/sites\/4\/61amuvxtqcl-1024x1024.webp 1024w, https:\/\/enertik.com\/mx\/wp-content\/uploads\/sites\/4\/61amuvxtqcl-768x768.webp 768w, https:\/\/enertik.com\/mx\/wp-content\/uploads\/sites\/4\/61amuvxtqcl-430x430.webp 430w, https:\/\/enertik.com\/mx\/wp-content\/uploads\/sites\/4\/61amuvxtqcl-700x700.webp 700w, https:\/\/enertik.com\/mx\/wp-content\/uploads\/sites\/4\/61amuvxtqcl.webp 1500w\" title=\"\">\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t<div class=\"elementor-column elementor-col-33 elementor-top-column elementor-element elementor-element-daf0308\" data-id=\"daf0308\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-4b2c66c elementor-widget elementor-widget-image\" data-id=\"4b2c66c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"150\" height=\"150\" src=\"https:\/\/enertik.com\/mx\/wp-content\/themes\/woodmart\/images\/lazy.svg\" class=\"attachment-thumbnail size-thumbnail wp-image-32615 wd-lazy-fade\" alt=\"Cables el\u00e9ctricos rojos y negros organizados sobre una superficie de madera para conexiones seguras.\" data-src=\"https:\/\/enertik.com\/mx\/wp-content\/uploads\/sites\/4\/dsc02760-scaled-1-150x150.webp\" srcset=\"\" title=\"\">\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"wd-negative-gap elementor-section elementor-top-section elementor-element elementor-element-a582fbf elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"a582fbf\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-659891a\" data-id=\"659891a\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-d3320a2 elementor-widget__width-initial color-scheme-inherit text-left elementor-widget elementor-widget-text-editor\" data-id=\"d3320a2\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"4243\" data-end=\"4344\"><span style=\"color: #000000;\">Transportan corriente continua desde el banco de bater\u00edas al inversor h\u00edbrido o al inversor cargador.<\/span><\/p><ul data-start=\"4346\" data-end=\"4546\"><li data-start=\"4346\" data-end=\"4448\"><p data-start=\"4348\" data-end=\"4448\"><span style=\"color: #000000;\">Deben tener una secci\u00f3n adecuada para manejar altas corrientes (por ejemplo, 50A, 100A, 200A o m\u00e1s).<\/span><\/p><\/li><li data-start=\"4449\" data-end=\"4546\"><p data-start=\"4451\" data-end=\"4546\"><span style=\"color: #000000;\">Generalmente son cables flexibles de cobre, con aislamiento grueso y resistencia a temperatura.<\/span><\/p><\/li><\/ul><hr \/><p data-start=\"4548\" data-end=\"4731\"><span style=\"color: #000000;\"><br \/>\ud83d\udc49 <strong data-start=\"4551\" data-end=\"4571\">\u00bfC\u00f3mo se eligen?<br \/><\/strong><\/span><br data-start=\"4571\" data-end=\"4574\" \/><span style=\"color: #000000;\">Seg\u00fan la corriente m\u00e1xima de descarga del banco de bater\u00edas. Se busca minimizar el calentamiento y la ca\u00edda de tensi\u00f3n. por lo tanto se recomienda que la longitud de cables entre el banco de bater\u00edas y el inversor no sea mayor que 2 metros. <br \/><\/span><\/p><p data-start=\"4548\" data-end=\"4731\"><span style=\"color: #000000;\">La corriente m\u00e1xima de descarga del banco de bater\u00edas se puede calcular con la potencia m\u00e1xima que puede requerir el inversor y la tensi\u00f3n del sistema. (e.g. 5000 W \/ 48 V = 105 A). A continuaci\u00f3n, te presentamos una tabla de referencia para la elecci\u00f3n del secci\u00f3n transversal adecuado :\u00a0<\/span><\/p><table dir=\"ltr\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\" data-sheets-root=\"1\" data-sheets-baot=\"1\"><colgroup> <col width=\"166\" \/> <col width=\"166\" \/> <col width=\"166\" \/> <col width=\"166\" \/> <col width=\"166\" \/><\/colgroup><tbody><tr><td><span style=\"color: #000000;\"><strong>Corriente m\u00e1x.<\/strong><\/span><\/td><td><span style=\"color: #000000;\"><strong>Potencia en pico &#8211; Inversor de 12V<\/strong><\/span><br \/><span style=\"color: #000000;\"><strong>(Aproximadamente)<\/strong><\/span><\/td><td><span style=\"color: #000000;\"><strong>Potencia en pico &#8211; Inversor de 24V<\/strong><\/span><br \/><span style=\"color: #000000;\"><strong>(Aproximadamente)<\/strong><\/span><\/td><td><span style=\"color: #000000;\"><strong>Potencia en pico &#8211; Inversor de 48V<\/strong><\/span><br \/><span style=\"color: #000000;\"><strong>(Aproximadamente)<\/strong><\/span><\/td><td><span style=\"color: #000000;\"><strong>Secci\u00f3n del cable adecuado<\/strong><\/span><\/td><\/tr><tr><td><span style=\"color: #000000;\"><strong>30 A<\/strong><\/span><\/td><td><span style=\"color: #000000;\">360 VA<\/span><\/td><td><span style=\"color: #000000;\">720 VA<\/span><\/td><td><span style=\"color: #000000;\">1440 VA<\/span><\/td><td><span style=\"color: #000000;\">10 mm\u00b2<\/span><\/td><\/tr><tr><td><span style=\"color: #000000;\"><strong>45 A<\/strong><\/span><\/td><td><span style=\"color: #000000;\">540 VA<\/span><\/td><td><span style=\"color: #000000;\">1080 VA<\/span><\/td><td><span style=\"color: #000000;\">2160 VA<\/span><\/td><td><span style=\"color: #000000;\">16 mm\u00b2<\/span><\/td><\/tr><tr><td><span style=\"color: #000000;\"><strong>75 A<\/strong><\/span><\/td><td><span style=\"color: #000000;\">900 VA<\/span><\/td><td><span style=\"color: #000000;\">1800 VA<\/span><\/td><td><span style=\"color: #000000;\">3600 VA<\/span><\/td><td><span style=\"color: #000000;\">25 mm\u00b2<\/span><\/td><\/tr><tr><td><span style=\"color: #000000;\"><strong>100 A<\/strong><\/span><\/td><td><span style=\"color: #000000;\">1200 VA<\/span><\/td><td><span style=\"color: #000000;\">2400 VA<\/span><\/td><td><span style=\"color: #000000;\">4800 VA<\/span><\/td><td><span style=\"color: #000000;\">35 mm\u00b2<\/span><\/td><\/tr><tr><td><span style=\"color: #000000;\"><strong>150 A<\/strong><\/span><\/td><td><span style=\"color: #000000;\">1800 VA<\/span><\/td><td><span style=\"color: #000000;\">3600 VA<\/span><\/td><td><span style=\"color: #000000;\">7200 VA<\/span><\/td><td><span style=\"color: #000000;\">50 mm\u00b2<\/span><\/td><\/tr><tr><td><span style=\"color: #000000;\"><strong>200 A<\/strong><\/span><\/td><td><span style=\"color: #000000;\">2400 VA<\/span><\/td><td><span style=\"color: #000000;\">4800 VA<\/span><\/td><td><span style=\"color: #000000;\">9600 VA<\/span><\/td><td><span style=\"color: #000000;\">70 mm\u00b2<\/span><\/td><\/tr><tr><td><span style=\"color: #000000;\"><strong>280 A<\/strong><\/span><\/td><td><span style=\"color: #000000;\">3360 VA<\/span><\/td><td><span style=\"color: #000000;\">6720 VA<\/span><\/td><td><span style=\"color: #000000;\">13440 VA<\/span><\/td><td><span style=\"color: #000000;\">95 mm\u00b2<\/span><\/td><\/tr><tr><td><span style=\"color: #000000;\"><strong>360 A<\/strong><\/span><\/td><td><span style=\"color: #000000;\">4320 VA<\/span><\/td><td><span style=\"color: #000000;\">8640 VA<\/span><\/td><td><span style=\"color: #000000;\">17280 VA<\/span><\/td><td><span style=\"color: #000000;\">120 mm\u00b2<\/span><\/td><\/tr><\/tbody><\/table>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"wd-negative-gap elementor-section elementor-top-section elementor-element elementor-element-19c8c77 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"19c8c77\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-191ef6e\" data-id=\"191ef6e\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-6008c8c color-scheme-inherit text-left elementor-widget elementor-widget-text-editor\" data-id=\"6008c8c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<h3 style=\"text-align: center;\" data-start=\"4738\" data-end=\"4785\"><span style=\"text-decoration: underline; color: #000000;\"><strong data-start=\"4742\" data-end=\"4785\">Protector t\u00e9rmico CC o Fusibles 12x42mm<\/strong><\/span><\/h3>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"wd-negative-gap elementor-section elementor-top-section elementor-element elementor-element-ec71374 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"ec71374\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-top-column elementor-element elementor-element-7ca2217\" data-id=\"7ca2217\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-839b662 elementor-widget elementor-widget-image\" data-id=\"839b662\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"150\" height=\"150\" src=\"https:\/\/enertik.com\/mx\/wp-content\/themes\/woodmart\/images\/lazy.svg\" class=\"attachment-thumbnail size-thumbnail wp-image-32616 wd-lazy-fade\" alt=\"Mini interruptor termomagn\u00e9tico de 2 polos EnerTik para protecci\u00f3n el\u00e9ctrica en instalaciones.\" srcset=\"\" sizes=\"(max-width: 150px) 100vw, 150px\" data-src=\"https:\/\/enertik.com\/mx\/wp-content\/uploads\/sites\/4\/protector-termico-2p-yjb1z-150x150.webp\" data-srcset=\"https:\/\/enertik.com\/mx\/wp-content\/uploads\/sites\/4\/protector-termico-2p-yjb1z-150x150.webp 150w, https:\/\/enertik.com\/mx\/wp-content\/uploads\/sites\/4\/protector-termico-2p-yjb1z-300x300.webp 300w, https:\/\/enertik.com\/mx\/wp-content\/uploads\/sites\/4\/protector-termico-2p-yjb1z-768x768.webp 768w, https:\/\/enertik.com\/mx\/wp-content\/uploads\/sites\/4\/protector-termico-2p-yjb1z-430x430.webp 430w, https:\/\/enertik.com\/mx\/wp-content\/uploads\/sites\/4\/protector-termico-2p-yjb1z-700x700.webp 700w, https:\/\/enertik.com\/mx\/wp-content\/uploads\/sites\/4\/protector-termico-2p-yjb1z.webp 1000w\" title=\"\">\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-top-column elementor-element elementor-element-f9b6f20\" data-id=\"f9b6f20\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-fd3c450 elementor-widget elementor-widget-image\" data-id=\"fd3c450\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"150\" height=\"150\" src=\"https:\/\/enertik.com\/mx\/wp-content\/themes\/woodmart\/images\/lazy.svg\" class=\"attachment-thumbnail size-thumbnail wp-image-32617 wd-lazy-fade\" alt=\"Fuse link de alta calidad para sistemas el\u00e9ctricos y dispositivos automotrices.\" data-src=\"https:\/\/enertik.com\/mx\/wp-content\/uploads\/sites\/4\/mega-fuse-victron-1-150x150.webp\" srcset=\"\" title=\"\">\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"wd-negative-gap elementor-section elementor-top-section elementor-element elementor-element-174fdaa elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"174fdaa\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-0f92ca9\" data-id=\"0f92ca9\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-397f7f4 elementor-widget__width-initial color-scheme-inherit text-left elementor-widget elementor-widget-text-editor\" data-id=\"397f7f4\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"4786\" data-end=\"4901\"><span style=\"color: #000000;\">Estos dispositivos protegen el sistema ante <strong data-start=\"4830\" data-end=\"4900\">sobrecorrientes causadas por fallas en los cables, las bater\u00edas o en el inversor<\/strong>.<\/span><\/p><ul data-start=\"4903\" data-end=\"5145\"><li data-start=\"4903\" data-end=\"5015\"><p data-start=\"4905\" data-end=\"5015\"><span style=\"color: #000000;\"><strong data-start=\"4905\" data-end=\"4930\">Protector t\u00e9rmico CC:<\/strong> normalmente se usa para bajas corrientes (como en instalaciones peque\u00f1as donde la corriente no supera los 50~100A).<\/span><\/p><\/li><li data-start=\"5016\" data-end=\"5145\"><p data-start=\"5018\" data-end=\"5145\"><span style=\"color: #000000;\"><strong data-start=\"5018\" data-end=\"5044\">Fusibles tipo 12x42mm:<\/strong> ideales para corrientes mayores, ofrecen corte r\u00e1pido y alta capacidad de interrupci\u00f3n.<\/span><\/p><\/li><\/ul><hr \/><p data-start=\"5147\" data-end=\"5337\"><span style=\"color: #000000;\"><br \/>\ud83d\udc49 <strong data-start=\"5150\" data-end=\"5170\">\u00bfC\u00f3mo se eligen?<br \/><\/strong><\/span><br data-start=\"5170\" data-end=\"5173\" \/><span style=\"color: #000000;\">Seg\u00fan la corriente nominal del inversor o del banco de bater\u00edas. Deben estar dimensionados para proteger los cables y dispositivos sin dispararse por el uso normal.\u00a0<\/span><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"wd-negative-gap elementor-section elementor-top-section elementor-element elementor-element-29e7c3f elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"29e7c3f\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-7fd82f7\" data-id=\"7fd82f7\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-ecd8f97 color-scheme-inherit text-left elementor-widget elementor-widget-text-editor\" data-id=\"ecd8f97\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<h3 style=\"text-align: center;\" data-start=\"5344\" data-end=\"5371\"><span style=\"text-decoration: underline;\"><span style=\"color: #000000; text-decoration: underline;\">Terminales de conexi\u00f3n crimpados para cables de bater\u00eda<\/span><\/span><\/h3>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"wd-negative-gap elementor-section elementor-top-section elementor-element elementor-element-5627a74 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"5627a74\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-199d80a\" data-id=\"199d80a\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-3fb818e elementor-widget elementor-widget-image\" data-id=\"3fb818e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"150\" height=\"150\" src=\"https:\/\/enertik.com\/mx\/wp-content\/themes\/woodmart\/images\/lazy.svg\" class=\"attachment-thumbnail size-thumbnail wp-image-32618 wd-lazy-fade\" alt=\"Conectores met\u00e1licos SC10-6 para terminales de bater\u00eda, ideales para conexiones el\u00e9ctricas seguras.\" srcset=\"\" sizes=\"(max-width: 150px) 100vw, 150px\" data-src=\"https:\/\/enertik.com\/mx\/wp-content\/uploads\/sites\/4\/terminal-ojal-para-baterias-sc10-6-150x150.webp\" data-srcset=\"https:\/\/enertik.com\/mx\/wp-content\/uploads\/sites\/4\/terminal-ojal-para-baterias-sc10-6-150x150.webp 150w, https:\/\/enertik.com\/mx\/wp-content\/uploads\/sites\/4\/terminal-ojal-para-baterias-sc10-6-300x300.webp 300w, https:\/\/enertik.com\/mx\/wp-content\/uploads\/sites\/4\/terminal-ojal-para-baterias-sc10-6-768x768.webp 768w, https:\/\/enertik.com\/mx\/wp-content\/uploads\/sites\/4\/terminal-ojal-para-baterias-sc10-6-430x430.webp 430w, https:\/\/enertik.com\/mx\/wp-content\/uploads\/sites\/4\/terminal-ojal-para-baterias-sc10-6-700x700.webp 700w, https:\/\/enertik.com\/mx\/wp-content\/uploads\/sites\/4\/terminal-ojal-para-baterias-sc10-6.webp 1000w\" title=\"\">\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"wd-negative-gap elementor-section elementor-top-section elementor-element elementor-element-a7afe88 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"a7afe88\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-7aebbe0\" data-id=\"7aebbe0\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-9e7a288 elementor-widget__width-initial color-scheme-inherit text-left elementor-widget elementor-widget-text-editor\" data-id=\"9e7a288\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p><span style=\"color: #000000;\">Los <strong data-start=\"213\" data-end=\"239\">terminales de conexi\u00f3n<\/strong> son un elemento fundamental en las conexiones de corriente continua de alta intensidad, como las que unen las bater\u00edas entre s\u00ed y las que conectan el banco de bater\u00edas con el inversor solar. Su funci\u00f3n es garantizar una uni\u00f3n <strong data-start=\"425\" data-end=\"477\">segura, duradera y de baja resistencia el\u00e9ctrica<\/strong> entre el cable y los bornes del equipo.<\/span><\/p><hr \/><p data-start=\"519\" data-end=\"540\"><strong><span style=\"color: #000000;\"><br \/>\u00bfC\u00f3mo funcionan?<\/span><\/strong><\/p><p><span style=\"color: #000000;\">Los cables de bater\u00eda, generalmente de gran secci\u00f3n (desde 10 mm\u00b2 hasta 95 mm\u00b2 o m\u00e1s), no pueden insertarse directamente en los bornes del inversor o la bater\u00eda. Por ello se utiliza un terminal de cobre o cobre esta\u00f1ado que se <strong data-start=\"769\" data-end=\"779\">crimpa<\/strong> (se prensa mec\u00e1nicamente) al extremo del cable, permitiendo as\u00ed un contacto firme y estandarizado.<\/span><\/p><hr \/><p data-start=\"880\" data-end=\"919\"><span style=\"color: #000000;\"><br \/>\ud83d\udc49 <strong data-start=\"5150\" data-end=\"5170\">\u00bfC\u00f3mo se eligen?<\/strong><\/span><\/p><p><span style=\"color: #000000;\">Hay dos criterios principales:<\/span><\/p><ol data-start=\"953\" data-end=\"1539\"><li data-start=\"953\" data-end=\"1088\"><span style=\"color: #000000;\"><strong data-start=\"956\" data-end=\"978\">Di\u00e1metro del cable<\/strong>: El cuerpo del terminal debe coincidir con la secci\u00f3n del cable (por ejemplo, terminal para cable de 35 mm\u00b2).<\/span><\/li><li data-start=\"1090\" data-end=\"1539\"><span style=\"color: #000000;\"><strong data-start=\"1093\" data-end=\"1124\">Tipo de conexi\u00f3n del equipo<\/strong>:<\/span><br \/><ul data-start=\"1131\" data-end=\"1539\"><li data-start=\"1131\" data-end=\"1269\"><span style=\"color: #000000;\"><strong data-start=\"1133\" data-end=\"1152\">Para inversores<\/strong>: Algunos utilizan <strong data-start=\"1171\" data-end=\"1206\">tornillo m\u00e9trico (M6, M8, etc.)<\/strong>, mientras otros emplean <strong data-start=\"1231\" data-end=\"1248\">bornes planos<\/strong> o barras de cobre.<\/span><\/li><li data-start=\"1273\" data-end=\"1539\"><span style=\"color: #000000;\"><strong data-start=\"1275\" data-end=\"1292\">Para bater\u00edas<\/strong>: Var\u00edan seg\u00fan el tipo (gel, litio, plomo \u00e1cido), pero com\u00fanmente usan <strong data-start=\"1363\" data-end=\"1382\">roscas M8 o M10<br \/><\/strong><\/span><span style=\"color: #000000;\">&#8211;&gt; En este caso se debe elegir el <strong data-start=\"1424\" data-end=\"1449\">orificio del terminal<\/strong> adecuado al tornillo o perno del equipo (por ejemplo, orificio de 8 mm para terminal M8).<\/span><\/li><\/ul><\/li><\/ol><hr \/><p data-start=\"1541\" data-end=\"1564\"><span style=\"color: #000000;\"><br \/>\ud83e\uddf0 <strong>Recomendaciones<\/strong><\/span><\/p><ul data-start=\"4903\" data-end=\"5145\"><li data-start=\"1566\" data-end=\"1657\"><span style=\"color: #000000;\">Utiliza <strong data-start=\"1576\" data-end=\"1608\">terminales de cobre esta\u00f1ado<\/strong> para prevenir la corrosi\u00f3n en ambientes h\u00famedos.<\/span><\/li><li data-start=\"1658\" data-end=\"1791\"><span style=\"color: #000000;\">Aseg\u00farate de usar una <strong data-start=\"1682\" data-end=\"1739\">prensadora (crimpadora) adecuada al calibre del cable<\/strong>, preferiblemente hidr\u00e1ulica para secciones grandes.<\/span><\/li><li data-start=\"1792\" data-end=\"1921\"><span style=\"color: #000000;\">No uses terminales tipo \u201cojo\u201d demasiado peque\u00f1os que puedan crear cuellos de botella t\u00e9rmicos o dificultar el apriete correcto.<\/span><\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"wd-negative-gap elementor-section elementor-top-section elementor-element elementor-element-ecb1e20 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"ecb1e20\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-67d135f\" data-id=\"67d135f\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-bf5b466 elementor-widget elementor-widget-heading\" data-id=\"bf5b466\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h1 class=\"elementor-heading-title elementor-size-default\">4. Conexi\u00f3n entre el inversor y los equipos (salida CA)<\/h1>\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"wd-negative-gap elementor-section elementor-top-section elementor-element elementor-element-e626e3a elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"e626e3a\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-ed858d0\" data-id=\"ed858d0\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-7039aef color-scheme-inherit text-left elementor-widget elementor-widget-text-editor\" data-id=\"7039aef\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<h3 style=\"text-align: center;\" data-start=\"5796\" data-end=\"5824\"><span style=\"text-decoration: underline; color: #000000;\">Cables de conexi\u00f3n CA<\/span><\/h3>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"wd-negative-gap elementor-section elementor-top-section elementor-element elementor-element-831cba3 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"831cba3\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-6fb5ac0\" data-id=\"6fb5ac0\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-a639729 elementor-widget elementor-widget-image\" data-id=\"a639729\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"300\" height=\"131\" src=\"https:\/\/enertik.com\/mx\/wp-content\/themes\/woodmart\/images\/lazy.svg\" class=\"attachment-medium size-medium wp-image-32619 wd-lazy-fade\" alt=\"Corte de cable el\u00e9ctrico con n\u00facleo de cobre y aislamiento de PVC rojo para seguridad.\" srcset=\"\" sizes=\"(max-width: 300px) 100vw, 300px\" data-src=\"https:\/\/enertik.com\/mx\/wp-content\/uploads\/sites\/4\/ejemplo-cable-ca-300x131.webp\" data-srcset=\"https:\/\/enertik.com\/mx\/wp-content\/uploads\/sites\/4\/ejemplo-cable-ca-300x131.webp 300w, https:\/\/enertik.com\/mx\/wp-content\/uploads\/sites\/4\/ejemplo-cable-ca-1024x448.webp 1024w, https:\/\/enertik.com\/mx\/wp-content\/uploads\/sites\/4\/ejemplo-cable-ca-768x336.webp 768w, https:\/\/enertik.com\/mx\/wp-content\/uploads\/sites\/4\/ejemplo-cable-ca-430x188.webp 430w, https:\/\/enertik.com\/mx\/wp-content\/uploads\/sites\/4\/ejemplo-cable-ca-700x306.webp 700w, https:\/\/enertik.com\/mx\/wp-content\/uploads\/sites\/4\/ejemplo-cable-ca-150x66.webp 150w, https:\/\/enertik.com\/mx\/wp-content\/uploads\/sites\/4\/ejemplo-cable-ca.webp 1350w\" title=\"\">\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"wd-negative-gap elementor-section elementor-top-section elementor-element elementor-element-b7f95ee elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"b7f95ee\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-72a5f94\" data-id=\"72a5f94\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-25863fc elementor-widget__width-initial color-scheme-inherit text-left elementor-widget elementor-widget-text-editor\" data-id=\"25863fc\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p><span style=\"color: #000000;\">Estos cables transportan corriente alterna desde el inversor hacia el tablero o los equipos. Son conductores flexibles con aislamiento en PVC, adecuados para instalaciones interiores fijas o m\u00f3viles.<\/span><\/p><hr \/><p><span style=\"color: #000000;\"><br \/>\ud83d\udc49 <strong data-start=\"7681\" data-end=\"7700\">\u00bfC\u00f3mo se elige?<br \/><\/strong><\/span><br data-start=\"7700\" data-end=\"7703\" \/><span style=\"color: #000000;\">Seg\u00fan la corriente que se va a transportar y la longitud del tendido. Es pr\u00e1ctico y reduce errores de conexi\u00f3n. A continuaci\u00f3n, te presentamos una tabla de referencia para la elecci\u00f3n del secci\u00f3n transversal adecuado <\/span><\/p><table dir=\"ltr\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\" data-sheets-root=\"1\" data-sheets-baot=\"1\"><colgroup> <col width=\"192\" \/> <col width=\"192\" \/> <col width=\"192\" \/> <col width=\"192\" \/><\/colgroup><tbody><tr><td><strong><span style=\"color: #000000;\">Potencia a 220 Vca<br \/>Monof\u00e1sica<\/span><\/strong><\/td><td><strong><span style=\"color: #000000;\">Corriente<\/span><\/strong><\/td><td><strong><span style=\"color: #000000;\">Secci\u00f3n de cable adecuado<\/span><\/strong><br \/><strong><span style=\"color: #000000;\">para un circuito hasta 10 m<\/span><\/strong><\/td><td><strong><span style=\"color: #000000;\">Secci\u00f3n de cable adecuado<\/span><\/strong><br \/><strong><span style=\"color: #000000;\">para un circuito hasta 20 m<\/span><\/strong><\/td><\/tr><tr><td><strong><span style=\"color: #000000;\">1,000 W<\/span><\/strong><\/td><td><span style=\"color: #000000;\">4.5 A<\/span><\/td><td><span style=\"color: #000000;\">1.5 mm\u00b2<\/span><\/td><td><span style=\"color: #000000;\">1.5 mm\u00b2<\/span><\/td><\/tr><tr><td><strong><span style=\"color: #000000;\">2,000 W<\/span><\/strong><\/td><td><span style=\"color: #000000;\">9 A<\/span><\/td><td><span style=\"color: #000000;\">1.5 mm\u00b2<\/span><\/td><td><span style=\"color: #000000;\">2.5 mm\u00b2<\/span><\/td><\/tr><tr><td><strong><span style=\"color: #000000;\">3,000 W<\/span><\/strong><\/td><td><span style=\"color: #000000;\">13.6 A<\/span><\/td><td><span style=\"color: #000000;\">2.5 mm\u00b2<\/span><\/td><td><span style=\"color: #000000;\">4 mm\u00b2<\/span><\/td><\/tr><tr><td><strong><span style=\"color: #000000;\">4,000 W<\/span><\/strong><\/td><td><span style=\"color: #000000;\">18.2 A<\/span><\/td><td><span style=\"color: #000000;\">4 mm\u00b2<\/span><\/td><td><span style=\"color: #000000;\">6 mm\u00b2<\/span><\/td><\/tr><tr><td><strong><span style=\"color: #000000;\">5,000 W<\/span><\/strong><\/td><td><span style=\"color: #000000;\">22.7 A<\/span><\/td><td><span style=\"color: #000000;\">4 mm\u00b2<\/span><\/td><td><span style=\"color: #000000;\">6 mm\u00b2<\/span><\/td><\/tr><tr><td><strong><span style=\"color: #000000;\">6,000 W<\/span><\/strong><\/td><td><span style=\"color: #000000;\">27.3 A<\/span><\/td><td><span style=\"color: #000000;\">6 mm\u00b2<\/span><\/td><td><span style=\"color: #000000;\">10 mm\u00b2<\/span><\/td><\/tr><tr><td><strong><span style=\"color: #000000;\">7,000 W<\/span><\/strong><\/td><td><span style=\"color: #000000;\">31.8 A<\/span><\/td><td><span style=\"color: #000000;\">6 mm\u00b2<\/span><\/td><td><span style=\"color: #000000;\">10 mm\u00b2<\/span><\/td><\/tr><tr><td><strong><span style=\"color: #000000;\">8,000 W<\/span><\/strong><\/td><td><span style=\"color: #000000;\">36.4 A<\/span><\/td><td><span style=\"color: #000000;\">10 mm\u00b2<\/span><\/td><td><span style=\"color: #000000;\">16 mm\u00b2<\/span><\/td><\/tr><tr><td><strong><span style=\"color: #000000;\">10,000 W<\/span><\/strong><\/td><td><span style=\"color: #000000;\">45.4 A<\/span><\/td><td><span style=\"color: #000000;\">10 mm\u00b2<\/span><\/td><td><span style=\"color: #000000;\">16 mm\u00b2<\/span><\/td><\/tr><\/tbody><\/table>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"wd-negative-gap elementor-section elementor-top-section elementor-element elementor-element-8b983c5 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"8b983c5\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-4712b5b\" data-id=\"4712b5b\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-8bdd388 elementor-widget elementor-widget-heading\" data-id=\"8bdd388\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h1 class=\"elementor-heading-title elementor-size-default\">Calculadora de secci\u00f3n de cables para DC y AC<\/h1>\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"wd-negative-gap elementor-section elementor-top-section elementor-element elementor-element-2e8499c elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"2e8499c\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-6d168fd\" data-id=\"6d168fd\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-e0c0589 elementor-widget elementor-widget-html\" data-id=\"e0c0589\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"html.default\">\n\t\t\t\t\t  <div class=\"enertik-calc\"><!-- wrapper para scope de estilos -->\n    <div class=\"enertik-container\">\n      <div class=\"enertik-card\">\n        <header class=\"enertik-card-header\">\n          <h1>\u26a1 Calculadora de Cables<\/h1>\n          <p>Determine la secci\u00f3n del cable seg\u00fan la ca\u00edda de tensi\u00f3n.<\/p>\n        <\/header>\n\n        <main class=\"enertik-card-body\">\n          <form id=\"calculator-form\" novalidate>\n            <div class=\"form-group\">\n              <label for=\"circuit-type\"><strong>Tipo de Circuito<\/strong><\/label>\n              <select id=\"circuit-type\">\n                <option value=\"dc\">CC (Corriente Continua)<\/option>\n                <option value=\"ac-mono\">AC 1~ (Alterna Monof\u00e1sica)<\/option>\n                <option value=\"ac-tri\">AC 3~ (Alterna Trif\u00e1sica)<\/option>\n              <\/select>\n            <\/div>\n\n            <div class=\"form-row\">\n              <div class=\"form-group\">\n                <label for=\"voltage\"><strong>Voltaje (V)<\/strong><\/label>\n                <input type=\"number\" id=\"voltage\" placeholder=\"12\" required min=\"0\" step=\"0.5\" inputmode=\"decimal\" \/>\n              <\/div>\n              <div class=\"form-group\">\n                <label for=\"current\"><strong>Corriente (A)<\/strong><\/label>\n                <input type=\"number\" id=\"current\" placeholder=\"100\" required min=\"0\" step=\"0.5\" inputmode=\"decimal\" \/>\n              <\/div>\n              <div class=\"form-group\">\n                <label for=\"length\"><strong>Largo (m)<\/strong><\/label>\n                <input type=\"number\" id=\"length\" placeholder=\"2\" required min=\"0\" step=\"0.5\" inputmode=\"decimal\" \/>\n              <\/div>\n            <\/div>\n\n            <button type=\"submit\" class=\"calculate-btn\">Calcular<\/button>\n          <\/form>\n\n          <div class=\"equivalence-link-container\">\n            <a href=\"#\" id=\"open-modal-link\"><strong>Ver tabla de equivalencias AWG \u2194 mm\u00b2<\/strong><\/a>\n          <\/div>\n\n          <div id=\"advisory-box\" class=\"advisory\" role=\"note\" aria-live=\"polite\">\n            <div class=\"advisory-icon\" aria-hidden=\"true\">\u26a0\ufe0f<\/div>\n            <div class=\"advisory-text\">\n              <strong>Aviso:<\/strong> Lo ideal es mantener las ca\u00eddas de tensi\u00f3n en los cables alrededor del 1%. Ca\u00eddas superiores al 3% pueden reducir el rendimiento, provocar disparos de protecci\u00f3n y generar sobrecalentamiento en conductores y conexiones (referencia NEC\/IEC).\n            <\/div>\n          <\/div>\n        <\/main>\n      <\/div>\n\n      <div id=\"results-container\" class=\"results-card hidden\">\n        <div class=\"results-header\">\n          <h2>Opciones de Secci\u00f3n<\/h2>\n          <div class=\"unit-toggle\">\n            <button id=\"unit-mm2\" class=\"active\">mm\u00b2<\/button>\n            <button id=\"unit-awg\">AWG<\/button>\n          <\/div>\n        <\/div>\n\n        <div id=\"results-message\" class=\"results-message hidden\"><\/div>\n        <div id=\"results-list\"><\/div>\n\n        <div class=\"legend\" aria-label=\"Leyenda de colores\">\n          <p><span class=\"dot ok\"><\/span> Recomendado (&lt;3%)<\/p>\n          <p><span class=\"dot warn\"><\/span> No recomendado (3\u20135%)<\/p>\n          <p><span class=\"dot danger\"><\/span> Peligroso (&ge;5%)<\/p>\n        <\/div>\n      <\/div>\n    <\/div>\n\n    <div id=\"equivalence-modal\" class=\"modal-overlay hidden\">\n      <div class=\"modal-content\">\n        <button id=\"close-modal\" class=\"modal-close-btn\" aria-label=\"Cerrar\">&times;<\/button>\n        <h3>Tabla de Equivalencias<\/h3>\n        <p class=\"modal-subtitle\">Calibre AWG y su secci\u00f3n correspondiente en mm\u00b2.<\/p>\n        <div class=\"table-container\">\n          <table>\n            <thead>\n              <tr>\n                <th>AWG<\/th>\n                <th>Secci\u00f3n (mm\u00b2)<\/th>\n              <\/tr>\n            <\/thead>\n            <tbody id=\"equivalence-table-body\"><\/tbody>\n          <\/table>\n        <\/div>\n      <\/div>\n    <\/div>\n  <\/div>\n  \t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"wd-negative-gap elementor-section elementor-top-section elementor-element elementor-element-4cd3018 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"4cd3018\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-710c2b2\" data-id=\"710c2b2\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-c66a07f color-scheme-inherit text-left elementor-widget elementor-widget-text-editor\" data-id=\"c66a07f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<h3 style=\"text-align: center;\" data-start=\"5796\" data-end=\"5824\"><span style=\"text-decoration: underline; color: #000000;\">Protector t\u00e9rmico CA<\/span><\/h3>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"wd-negative-gap elementor-section elementor-top-section elementor-element elementor-element-2438881 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"2438881\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-b4e34ef\" data-id=\"b4e34ef\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-9f77f61 elementor-widget elementor-widget-image\" data-id=\"9f77f61\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"150\" height=\"150\" src=\"https:\/\/enertik.com\/mx\/wp-content\/themes\/woodmart\/images\/lazy.svg\" class=\"attachment-thumbnail size-thumbnail wp-image-32620 wd-lazy-fade\" alt=\"Interruptor autom\u00e1tico Schneider Electric xC60, compacto y eficiente para protecci\u00f3n de circuitos el\u00e9ctricos.\" srcset=\"\" sizes=\"(max-width: 150px) 100vw, 150px\" data-src=\"https:\/\/enertik.com\/mx\/wp-content\/uploads\/sites\/4\/ac-mcb-example-150x150.webp\" data-srcset=\"https:\/\/enertik.com\/mx\/wp-content\/uploads\/sites\/4\/ac-mcb-example-150x150.webp 150w, https:\/\/enertik.com\/mx\/wp-content\/uploads\/sites\/4\/ac-mcb-example-300x300.webp 300w, https:\/\/enertik.com\/mx\/wp-content\/uploads\/sites\/4\/ac-mcb-example-768x768.webp 768w, https:\/\/enertik.com\/mx\/wp-content\/uploads\/sites\/4\/ac-mcb-example-430x430.webp 430w, https:\/\/enertik.com\/mx\/wp-content\/uploads\/sites\/4\/ac-mcb-example-700x700.webp 700w, https:\/\/enertik.com\/mx\/wp-content\/uploads\/sites\/4\/ac-mcb-example.webp 800w\" title=\"\">\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"wd-negative-gap elementor-section elementor-top-section elementor-element elementor-element-09fa849 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"09fa849\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-c2c0c62\" data-id=\"c2c0c62\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-5b36812 elementor-widget__width-initial color-scheme-inherit text-left elementor-widget elementor-widget-text-editor\" data-id=\"5b36812\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"5825\" data-end=\"5982\"><span style=\"color: #000000;\">Act\u00faa como interruptor autom\u00e1tico que protege los equipos conectados a la salida del inversor frente a <strong data-start=\"5928\" data-end=\"5981\">sobrecargas o cortocircuitos en corriente alterna<\/strong>.<\/span><\/p><hr \/><p data-start=\"5984\" data-end=\"6178\"><span style=\"color: #000000;\"><br \/>\ud83d\udc49 <strong data-start=\"5987\" data-end=\"6006\">\u00bfC\u00f3mo se elige?<br \/><\/strong><\/span><br data-start=\"6006\" data-end=\"6009\" \/><span style=\"color: #000000;\">Seg\u00fan la potencia total que manejar\u00e1 el circuito y el calibre del cableado. Suele elegirse un disyuntor de 10A a 32A para usos residenciales, dependiendo de los equipos.<\/span><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"wd-negative-gap elementor-section elementor-top-section elementor-element elementor-element-144ad31 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"144ad31\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-a833fef\" data-id=\"a833fef\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-95ff285 color-scheme-inherit text-left elementor-widget elementor-widget-text-editor\" data-id=\"95ff285\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<h3 style=\"text-align: center;\" data-start=\"5796\" data-end=\"5824\"><span style=\"text-decoration: underline;\">Interruptor Diferencial (RCD) para protecci\u00f3n contra contactos indirectos<\/span><\/h3>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"wd-negative-gap elementor-section elementor-top-section elementor-element elementor-element-dcc4956 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"dcc4956\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-cfe2d7d\" data-id=\"cfe2d7d\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-f305cfc elementor-widget elementor-widget-image\" data-id=\"f305cfc\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"150\" height=\"150\" src=\"https:\/\/enertik.com\/mx\/wp-content\/themes\/woodmart\/images\/lazy.svg\" class=\"attachment-thumbnail size-thumbnail wp-image-32621 wd-lazy-fade\" alt=\"Interruptor diferencial Eaton para seguridad el\u00e9ctrica, con bot\u00f3n de prueba y dise\u00f1o compacto.\" data-src=\"https:\/\/enertik.com\/mx\/wp-content\/uploads\/sites\/4\/w9228702-01-150x150.webp\" srcset=\"\" title=\"\">\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"wd-negative-gap elementor-section elementor-top-section elementor-element elementor-element-6985c50 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"6985c50\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-f5d4650\" data-id=\"f5d4650\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-0ce2832 elementor-widget__width-initial color-scheme-inherit text-left elementor-widget elementor-widget-text-editor\" data-id=\"0ce2832\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"263\" data-end=\"672\"><span style=\"color: #000000;\">En la <strong data-start=\"269\" data-end=\"325\">salida AC del inversor hacia los consumos el\u00e9ctricos<\/strong>, adem\u00e1s de los protectores t\u00e9rmicos y contra sobretensiones, es indispensable incluir un <strong data-start=\"415\" data-end=\"473\">Interruptor Diferencial (RCD, Residual Current Device)<\/strong>. Su funci\u00f3n principal es <strong data-start=\"499\" data-end=\"565\">proteger a las personas contra descargas el\u00e9ctricas indirectas<\/strong>, es decir, en caso de que una persona entre en contacto con una parte met\u00e1lica accidentalmente energizada.<\/span><\/p><p data-start=\"674\" data-end=\"921\"><span style=\"color: #000000;\">Este dispositivo <strong data-start=\"691\" data-end=\"766\">detecta diferencias de corriente entre el conductor de fase y el neutro<\/strong> (lo que indica una fuga a tierra) y <strong data-start=\"803\" data-end=\"844\">desconecta el circuito inmediatamente<\/strong>, generalmente cuando la fuga supera los 30 mA en aplicaciones residenciales.<\/span><\/p><hr \/><p data-start=\"5984\" data-end=\"6178\"><span style=\"color: #000000;\"><br \/>\ud83d\udc49 <strong data-start=\"5987\" data-end=\"6006\">\u00bfC\u00f3mo se elige?<\/strong><\/span><\/p><ul data-start=\"962\" data-end=\"1504\"><li data-start=\"962\" data-end=\"1140\"><p data-start=\"964\" data-end=\"1140\"><span style=\"color: #000000;\"><strong data-start=\"964\" data-end=\"981\">Sensibilidad:<\/strong> Lo m\u00e1s habitual es 30 mA para protecci\u00f3n personal. En instalaciones industriales pueden usarse valores mayores si se combina con una puesta a tierra adecuada.<\/span><\/p><\/li><li data-start=\"1141\" data-end=\"1328\"><p data-start=\"1143\" data-end=\"1328\"><span style=\"color: #000000;\"><strong data-start=\"1143\" data-end=\"1165\">Tipo de corriente:<\/strong> Para instalaciones fotovoltaicas se recomienda como m\u00ednimo un <strong data-start=\"1228\" data-end=\"1242\">RCD tipo A<\/strong>, que puede detectar fugas tanto en corriente alterna pura como en corriente pulsante.<\/span><\/p><\/li><li data-start=\"1329\" data-end=\"1423\"><p data-start=\"1331\" data-end=\"1423\"><span style=\"color: #000000;\"><strong data-start=\"1331\" data-end=\"1351\">N\u00famero de polos:<\/strong> Monof\u00e1sico (2P) o trif\u00e1sico (4P), seg\u00fan el tipo de salida del inversor.<\/span><\/p><\/li><li data-start=\"1424\" data-end=\"1504\"><p data-start=\"1426\" data-end=\"1504\"><span style=\"color: #000000;\"><strong data-start=\"1426\" data-end=\"1448\">Corriente nominal:<\/strong> Igual o superior a la del interruptor t\u00e9rmico asociado.<\/span><\/p><\/li><\/ul><hr \/><p>\u00a0<\/p><p data-start=\"1506\" data-end=\"1525\"><strong><span style=\"color: #000000;\">\ud83d\udccc Instalaci\u00f3n<\/span><\/strong><\/p><p data-start=\"1527\" data-end=\"1734\"><span style=\"color: #000000;\">El RCD debe instalarse <strong data-start=\"1550\" data-end=\"1646\">despu\u00e9s del inversor, en la l\u00ednea de salida AC antes de distribuir la energ\u00eda a los consumos<\/strong>, y <strong data-start=\"1650\" data-end=\"1695\">en conjunto con el interruptor t\u00e9rmico CA<\/strong>, para ofrecer una protecci\u00f3n completa.<\/span><\/p><blockquote data-start=\"1736\" data-end=\"1983\"><p data-start=\"1738\" data-end=\"1983\"><span style=\"color: #000000;\">\u26a0\ufe0f <strong data-start=\"1741\" data-end=\"1756\">Importante:<\/strong> No todos los inversores generan un sistema con neutro real. En esos casos, el tipo de RCD y su comportamiento deben analizarse cuidadosamente. Consulta siempre el manual del fabricante del inversor o un profesional calificado.<\/span><\/p><\/blockquote>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"wd-negative-gap elementor-section elementor-top-section elementor-element elementor-element-9f2035c elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"9f2035c\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-5b754d6\" data-id=\"5b754d6\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-fa1f507 color-scheme-inherit text-left elementor-widget elementor-widget-text-editor\" data-id=\"fa1f507\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<h3 style=\"text-align: center;\" data-start=\"6185\" data-end=\"6231\"><span style=\"text-decoration: underline; color: #000000;\"><strong data-start=\"6189\" data-end=\"6231\">Protector de Descargas Atmosf\u00e9ricas CA<\/strong><\/span><\/h3>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"wd-negative-gap elementor-section elementor-top-section elementor-element elementor-element-bac4a35 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"bac4a35\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-f07def4\" data-id=\"f07def4\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-2967d6c elementor-widget elementor-widget-image\" data-id=\"2967d6c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"150\" height=\"150\" src=\"https:\/\/enertik.com\/mx\/wp-content\/themes\/woodmart\/images\/lazy.svg\" class=\"attachment-thumbnail size-thumbnail wp-image-32622 wd-lazy-fade\" alt=\"Protector de descargas atmosf\u00e9ricas ADM5-C, 385VCA, ideal para proteger sistemas el\u00e9ctricos de sobretensiones.\" srcset=\"\" sizes=\"(max-width: 150px) 100vw, 150px\" data-src=\"https:\/\/enertik.com\/mx\/wp-content\/uploads\/sites\/4\/protector-de-descargas-atmosfericas-385vca-1pn-adm5-2p-150x150.webp\" data-srcset=\"https:\/\/enertik.com\/mx\/wp-content\/uploads\/sites\/4\/protector-de-descargas-atmosfericas-385vca-1pn-adm5-2p-150x150.webp 150w, https:\/\/enertik.com\/mx\/wp-content\/uploads\/sites\/4\/protector-de-descargas-atmosfericas-385vca-1pn-adm5-2p-300x300.webp 300w, https:\/\/enertik.com\/mx\/wp-content\/uploads\/sites\/4\/protector-de-descargas-atmosfericas-385vca-1pn-adm5-2p-768x768.webp 768w, https:\/\/enertik.com\/mx\/wp-content\/uploads\/sites\/4\/protector-de-descargas-atmosfericas-385vca-1pn-adm5-2p-430x430.webp 430w, https:\/\/enertik.com\/mx\/wp-content\/uploads\/sites\/4\/protector-de-descargas-atmosfericas-385vca-1pn-adm5-2p-700x700.webp 700w, https:\/\/enertik.com\/mx\/wp-content\/uploads\/sites\/4\/protector-de-descargas-atmosfericas-385vca-1pn-adm5-2p.webp 1000w\" title=\"\">\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"wd-negative-gap elementor-section elementor-top-section elementor-element elementor-element-6bbad7f elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"6bbad7f\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-a768b75\" data-id=\"a768b75\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-93b23d2 elementor-widget__width-initial color-scheme-inherit text-left elementor-widget elementor-widget-text-editor\" data-id=\"93b23d2\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"6232\" data-end=\"6464\"><span style=\"color: #000000;\">Funciona igual que su versi\u00f3n en corriente continua, pero instalado <strong data-start=\"6300\" data-end=\"6348\">en la parte de corriente alterna del sistema<\/strong>. Protege electrodom\u00e9sticos, equipos inform\u00e1ticos, etc., de sobretensiones causadas por rayos o maniobras en la red.<\/span><\/p><p data-start=\"6466\" data-end=\"6646\"><span style=\"color: #000000;\"><br \/>\ud83d\udc49 <strong data-start=\"6469\" data-end=\"6488\">\u00bfC\u00f3mo se elige?<\/strong><\/span><br data-start=\"6488\" data-end=\"6491\" \/><span style=\"color: #000000;\">Seg\u00fan la tensi\u00f3n nominal de salida del inversor (110V o 220V), la clase de protecci\u00f3n requerida (I, II o combinada) y el entorno (urbano, rural, expuesto).<\/span><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"wd-negative-gap elementor-section elementor-top-section elementor-element elementor-element-c86701b elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"c86701b\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-d2da513\" data-id=\"d2da513\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-1308ec1 color-scheme-inherit text-left elementor-widget elementor-widget-text-editor\" data-id=\"1308ec1\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<h3 style=\"text-align: center;\" data-start=\"7051\" data-end=\"7104\"><span style=\"text-decoration: underline; color: #000000;\"><strong data-start=\"7055\" data-end=\"7104\">Cable de conexi\u00f3n a tierra CA<\/strong><\/span><\/h3>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"wd-negative-gap elementor-section elementor-top-section elementor-element elementor-element-6a7191c elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"6a7191c\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-16133dc\" data-id=\"16133dc\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-cf2d176 elementor-widget elementor-widget-image\" data-id=\"cf2d176\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"150\" height=\"150\" src=\"https:\/\/enertik.com\/mx\/wp-content\/themes\/woodmart\/images\/lazy.svg\" class=\"attachment-thumbnail size-thumbnail wp-image-32623 wd-lazy-fade\" alt=\"Cable el\u00e9ctrico con n\u00facleo de cobre y camisa aislante de PVC.\" data-src=\"https:\/\/enertik.com\/mx\/wp-content\/uploads\/sites\/4\/ejemplo-cable-tierra-150x150.webp\" srcset=\"\" title=\"\">\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"wd-negative-gap elementor-section elementor-top-section elementor-element elementor-element-83deeda elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"83deeda\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-5602449\" data-id=\"5602449\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-8fc90cb elementor-widget__width-initial color-scheme-inherit text-left elementor-widget elementor-widget-text-editor\" data-id=\"8fc90cb\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"7051\" data-end=\"7104\"><span style=\"color: #000000;\">Es indispensable conectar el sistema a tierra para evitar acumulaci\u00f3n de tensi\u00f3n peligrosa y cumplir con normativas el\u00e9ctricas. Estos cables van del inversor y la estructura met\u00e1lica a la jabalina de tierra. En caso de usar un inversor-cargador, se necesita la conexi\u00f3n a tierra tanto para el circuito de entrada como para el circuito de salida. Cada tipo de inversor o inversor-cargador puede proporcionar\/necesitar un m\u00e9todo de conexi\u00f3n a tierra distinto y algunos emplean el sistema de rel\u00e9 din\u00e1mico para la conexi\u00f3n a tierra. Consuten el manual del inversor para saber m\u00e1s detalles y realizar la conexi\u00f3n de forma correcta.<\/span><\/p><hr \/><p data-start=\"7314\" data-end=\"7479\"><span style=\"color: #000000;\"><br \/>\ud83d\udc49 <strong data-start=\"7317\" data-end=\"7336\">\u00bfC\u00f3mo se elige?<br \/><\/strong><\/span><br data-start=\"7336\" data-end=\"7339\" \/><span style=\"color: #000000;\">Seg\u00fan las normativas locales de puesta a tierra, la potencia total del sistema y la forma de conexi\u00f3n que proporciona el inversor.\u00a0<\/span><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"wd-negative-gap elementor-section elementor-top-section elementor-element elementor-element-c152352 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"c152352\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-7ed872c\" data-id=\"7ed872c\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-0567017 elementor-widget elementor-widget-heading\" data-id=\"0567017\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h1 class=\"elementor-heading-title elementor-size-default\">Conclusi\u00f3n<\/h1>\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"wd-negative-gap elementor-section elementor-top-section elementor-element elementor-element-3c1333f elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"3c1333f\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-240d45b\" data-id=\"240d45b\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-de655b8 elementor-widget__width-initial color-scheme-inherit text-left elementor-widget elementor-widget-text-editor\" data-id=\"de655b8\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"7836\" data-end=\"8266\"><span style=\"color: #000000;\">Cada uno de estos componentes es <strong data-start=\"7869\" data-end=\"7950\">una pieza cr\u00edtica para el funcionamiento seguro y estable de tu sistema solar<\/strong>. Desde los cables que garantizan una conexi\u00f3n duradera, hasta los protectores que act\u00faan ante una tormenta, todo cumple una funci\u00f3n precisa. Invertir en componentes certificados y bien seleccionados <strong data-start=\"8150\" data-end=\"8266\">no solo alarga la vida \u00fatil del sistema, sino que protege tus equipos, tu inversi\u00f3n y, sobre todo, tu seguridad.<\/strong><\/span><\/p><p data-start=\"8268\" data-end=\"8481\"><span style=\"color: #000000;\">En nuestra tienda encontrar\u00e1s todos estos elementos seleccionados por calidad, compatibilidad y certificaciones internacionales. Y si necesitas ayuda para elegir el modelo o tama\u00f1o adecuado, estamos para ayudarte.<\/span><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"wd-negative-gap elementor-section elementor-top-section elementor-element elementor-element-cb7b9eb elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"cb7b9eb\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-1e8df73\" data-id=\"1e8df73\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-be1e44d elementor-widget-divider--view-line elementor-widget elementor-widget-divider\" data-id=\"be1e44d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"divider.default\">\n\t\t\t\t\t\t\t<div class=\"elementor-divider\">\n\t\t\t<span class=\"elementor-divider-separator\">\n\t\t\t\t\t\t<\/span>\n\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"wd-negative-gap elementor-section elementor-top-section elementor-element elementor-element-9b18504 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"9b18504\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-c267b0b\" data-id=\"c267b0b\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-f9b3814 elementor-widget__width-initial color-scheme-inherit text-left elementor-widget elementor-widget-text-editor\" data-id=\"f9b3814\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"800\" data-end=\"837\"><span style=\"color: #000000;\"><strong data-start=\"800\" data-end=\"837\">Recomendaci\u00f3n de lectura t\u00e9cnica:<\/strong><\/span><\/p><p data-start=\"839\" data-end=\"1404\"><span style=\"color: #000000;\">Para los profesionales que buscan una referencia t\u00e9cnica confiable, el libro <em><a href=\"https:\/\/enertik.com\/wp-content\/uploads\/sites\/3\/documentos\/manuales\/43562-wiring_unlimited-pdf-es.pdf\"><span style=\"text-decoration: underline;\"><span style=\"color: #0000ff; text-decoration: underline;\"><strong data-start=\"920\" data-end=\"942\">Wiring Unlimited<\/strong> <strong>de <\/strong><\/span><\/span><strong data-start=\"946\" data-end=\"964\"><span style=\"text-decoration: underline;\"><span style=\"color: #0000ff; text-decoration: underline;\">Victron Energy (en espa\u00f1ol)<\/span><\/span><\/strong><\/a> <\/em>es una excelente gu\u00eda. Este manual proporciona criterios claros y actualizados para el dise\u00f1o y dimensionamiento de sistemas el\u00e9ctricos en instalaciones de energ\u00eda solar, incluyendo tablas de selecci\u00f3n de cables, recomendaciones de protecci\u00f3n, esquemas de conexi\u00f3n y buenas pr\u00e1cticas. Su consulta resulta especialmente \u00fatil en proyectos residenciales, comerciales o aislados donde la seguridad y la eficiencia del sistema son prioritarias.<\/span><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"wd-negative-gap elementor-section elementor-top-section elementor-element elementor-element-f0eba28 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"f0eba28\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-9d90924\" data-id=\"9d90924\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-f562573 elementor-widget__width-initial color-scheme-inherit text-left elementor-widget elementor-widget-text-editor\" data-id=\"f562573\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"180\" data-end=\"223\"><span style=\"color: #000000;\"><strong data-start=\"180\" data-end=\"223\">Advertencia sobre el uso de la informaci\u00f3n:<\/strong><\/span><\/p><p data-start=\"179\" data-end=\"596\"><span style=\"color: #000000;\">Este art\u00edculo tiene un prop\u00f3sito informativo y ofrece una visi\u00f3n general, simple y orientativa sobre los distintos elementos de conexi\u00f3n y protecci\u00f3n que conforman un sistema de distribuci\u00f3n el\u00e9ctrica con energ\u00eda solar. Las tablas de selecci\u00f3n de cables incluidas son meramente referenciales y no deben utilizarse como sustituto de c\u00e1lculos el\u00e9ctricos detallados ni del dise\u00f1o t\u00e9cnico adaptado a cada caso particular.<\/span><\/p><p data-start=\"598\" data-end=\"1136\"><span style=\"color: #000000;\">La elecci\u00f3n adecuada de cables, protecciones, conectores y dem\u00e1s componentes debe realizarse en base a la normativa el\u00e9ctrica vigente en el pa\u00eds de instalaci\u00f3n, considerando factores como la longitud del tendido, agrupamiento de conductores, tipo de instalaci\u00f3n, temperatura ambiente, y otros aspectos t\u00e9cnicos relevantes. Por lo tanto, <strong data-start=\"935\" data-end=\"1053\">toda la instalaci\u00f3n y selecci\u00f3n de componentes debe ser llevada a cabo por profesionales calificados y autorizados<\/strong>, que cuenten con competencias reconocidas oficialmente seg\u00fan la legislaci\u00f3n local.<\/span><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>En un sistema de energ\u00eda solar, cada elemento de conexi\u00f3n y protecci\u00f3n cumple una funci\u00f3n cr\u00edtica para garantizar el rendimiento, la seguridad y la durabilidad de la instalaci\u00f3n. Este art\u00edculo explica de forma detallada los componentes que intervienen en la distribuci\u00f3n el\u00e9ctrica de sistemas fotovoltaicos, desde cables y conectores hasta fusibles, protecciones contra sobretensiones, llaves de corte y terminales de bater\u00eda. Adem\u00e1s, se incluyen criterios pr\u00e1cticos para seleccionar el tipo adecuado seg\u00fan la corriente y la normativa aplicable, con ejemplos concretos que facilitan la elecci\u00f3n correcta en campo.<\/p>\n","protected":false},"author":4029,"featured_media":32597,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_relevanssi_hide_post":"","_relevanssi_hide_content":"","_relevanssi_pin_for_all":"","_relevanssi_pin_keywords":"","_relevanssi_unpin_keywords":"","_relevanssi_related_keywords":"","_relevanssi_related_include_ids":"","_relevanssi_related_exclude_ids":"","_relevanssi_related_no_append":"","_relevanssi_related_not_related":"","_relevanssi_related_posts":"","_relevanssi_noindex_reason":"","inline_featured_image":false,"footnotes":""},"categories":[1],"tags":[4767,4768,4769,4770,4771,4772,4773,4774,4775],"class_list":["post-32596","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-otras-soluciones","tag-cable-fotovoltaico","tag-cableado-solar-ca-y-cc","tag-distribucion-electrica-solar","tag-elementos-de-conexion-solar","tag-normativa-cableado-solar-en-50618","tag-proteccion-sistemas-solares","tag-seguridad-en-instalaciones-fotovoltaicas","tag-seguridad-instalacion-fotovoltaica","tag-sistemas-de-proteccion-fotovoltaicos"],"amp_enabled":true,"_links":{"self":[{"href":"https:\/\/enertik.com\/mx\/wp-json\/wp\/v2\/posts\/32596","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/enertik.com\/mx\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/enertik.com\/mx\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/enertik.com\/mx\/wp-json\/wp\/v2\/users\/4029"}],"replies":[{"embeddable":true,"href":"https:\/\/enertik.com\/mx\/wp-json\/wp\/v2\/comments?post=32596"}],"version-history":[{"count":0,"href":"https:\/\/enertik.com\/mx\/wp-json\/wp\/v2\/posts\/32596\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/enertik.com\/mx\/wp-json\/wp\/v2\/media\/32597"}],"wp:attachment":[{"href":"https:\/\/enertik.com\/mx\/wp-json\/wp\/v2\/media?parent=32596"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/enertik.com\/mx\/wp-json\/wp\/v2\/categories?post=32596"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/enertik.com\/mx\/wp-json\/wp\/v2\/tags?post=32596"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}